Cleave lengths can be confirmed on the 12.5mm length 

gauge. Cleave should be within the window.

6.1 Cut off rubber band, position actuation lever over splice, and 

lift both buffer clamps to the “up”position.

Confirm that buffer on pigtail is fully inserted inside 

splice and follow steps 7.2 through 7.9.

6.2

Splice/Holder Assembly 2539

7.0

7.2

Holding the fiber approximately ½ inch (13mm) from the 

bare glass, insert cleaved fiber into the guide on the right 

(actuation lever side) of the splice/holder until it stops inside 

the Fibrlok II splice.

Carefully mark the buffer at the right edge of the base.

Note: Always insert the fiber first on the right (actuation lever                 

side) of the splice/holder.

3M Fibrlok II Splice/Holder Pigtail Assembly                
2539 SC/APC and 2539 SC/UPC

5.5

Prepare second fiber (strip, clean and cleave) as described in 

section 5.

7.3

Holding the fiber approximately ½ inch (13mm) from the 

bare glass, insert second fiber into the guide on the left side 

(opposite actuation lever) of the splice/holder until it stops 

inside the Fibrlok II splice.

7.4

While sliding the second fiber into the splice, the mark on the 

first fiber should move outwards 1/8 inch (3mm) showing the 

fiber ends are in contact. If this is not observed, one or both 

fibers has a bad/short cleave. Remove one fiber and re-strip, 

clean, re-cleave and insert back into the splice. If contact is  

still not correct, repeat procedure for second fiber.

7.5

Note: To prevent contamination, never fully remove and re-

insert a cleaved end back into a splice without first re-stripping 

and re-cleaving.

Center both fiber cleaves by repositioning the mark on the first

fiber half way back to its original position.

7.6

Note: Cleavers must be in good operating condition and used per the manufacturer’s instructions. They 

should provide consistent cleave-to-coating lengths /- 0.5mm. Acceptable cleavers will produce 

cleaved ends within 0.5° of perpendicular (typical always <1 °), free from major defects.

6.0

7.1

Note: Push fiber straight into the fiber alignment guide, not at

an angle. Bare glass should not be visible outside of the splice. If 

bare glass is visible, pull back slightly on the fiber and continue 

insertion until resistance is met. Do not fully remove fibers from 

splice after initial insertion.

Once the fibers are centered, fully close the right buffer clamp. 

You will hear an audible snap.

7.7

Summary of Contents for Fibrlok II 2539

Page 1: ...50μm and 900μm coating diameters 1 0 General 1 1 2 0 Safety and Helpful Hints Note Carefully follow safety health and environmental information on the label or MSDS for isopropyl alcohol Storage use and disposal of isopropyl alcohol per your company health safety and environmental instructions Carefully follow safety health and environmental information on 3M Fibrlok II Splice label or Material Sa...

Page 2: ...r several seconds onto the surface of its final location Lift the buffer clamps at both ends of the splice holder and lift the actuation lever to the up position Note The 3M Fibrlok II Splice Holder is designed for 900μm tight buffer and 250μm primary coated fiber To splice 900μm loose tube semi tight or release layered fiber remove the 900μm coating within the last four inches or more from the fi...

Page 3: ...iber into the splice the mark on the first fiber should move outwards 1 8 inch 3mm showing the fiber ends are in contact If this is not observed one or both fibers has a bad short cleave Remove one fiber and re strip clean re cleave and insert back into the splice If contact is still not correct repeat procedure for second fiber 7 5 Note To prevent contamination never fully remove and re insert a ...

Page 4: ...low While the splice is still in the holder assembly lift the actuation lever and insert the cap removal tool over the splice cap Grasp both sides of the splice holder base and lift the cap up and off the splice while gently rocking lengthwise Replace the cap parallel to the top but raised about 1mm 0 04 inch as it snaps into place 7 8 Carefully reposition fiber Refer to section 7 0 for proper fib...

Reviews: