13
78-8135-6695-3-C
Ribbon
11.12 Mount ribbon fanout on backside of the splice tray
and secure with cable tie. Plug SC connector end into
HFOC adaptors as shown.
11.13 Recommend ribbon splicing be done with the splice
tray mounted inside the storage tray.
11.14 Replace cover and secure tray(s) by reattaching
retaining strap.
12.0 Closure Sealing
12.1 Ensure both the dome seal area and base O-ring
is free of dirt or any damage. If needed clean area
and apply a light film of supplied silicone lubricant.
Failure to maintain a clean seal area may lead to
leakage.
Note: Follow health, safety and environmental
information, refer to product label or Material Safety
Data Sheet for Silicone Lubricant.