6
78-8140-4883-7-A
6.0 Armored Main Cable Preparation
5.5” (140mm)
TRIM CSM ROD(S)
3.5”
(89mm)
LEAVE HALF OF CABLE SHEATH
W/METALLIC SHIELDING TO
ATTACH GROUNDING
MEASURE SHEATH OPENING
TO HERE
For Armored Cables Only
6.1
Install grounding kit onto tab of cable sheath
as shown.
3M
™
Internal Ground
Kit 6 AWG
3M
™
Internal Ground
Kit 14 AWG
6.2
Wrap sheath and ground terminal with tape to
protect fibers from sharp edges.
3M
™
Grounding Kits must be purchased separately:
ECAM-GND-6-AWG ...........................80-6113-1702-7
ECAM-GND-14-AWG .........................80-6113-1704-3
4460-D ..................................................80-6104-1486-6