General

Power

3M

 ESD Pro uses a 9V alkaline battery. Do not use any other type of battery. 

If you are not using your 3M

 ESD Pro for an extended period of time, 

remove the battery from the unit in order to prevent damage caused by battery 
leakage. Note: Not all batteries labeled similarly have the same performance. 
Often an off-brand alkaline battery has only 50% to 60% of the capacity of 
the leading brand-name battery.

Installing the Battery

Slide off the battery door at the back of 3M

 ESD Pro and attach the 9V 

battery to the battery clips. Observe the polarity of the battery. Re-install the 
battery door.

Low-Battery Indicator

When battery voltage gets low (less than ~20% capacity remains), the low 
battery indicator on the display appears. At this point it is a good idea to 
install a new battery to assure optimal performance.

Turning 3M

 ESD Pro On and Off

Move the actuator of the power slide switch to the right. The ESD event 
counter should display a number of captured events, usually “0” at this point. 
The events counter is reset when the power is turned off.

To turn the power off, move the actuator of power slide switch to the left. The 
3M

 ESD Pro has no automatic shut-off. Don’t forget to turn it off when not 

in active use.

Summary of Contents for ESD Pro

Page 1: ...3M ESD Pro User s Guide ESD Event Indicator Model CTM082...

Page 2: ...riodically check that the indicator is functioning properly FCC This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harm...

Page 3: ...solenoids stepper motors and alike In order to separate charge device type events from non related EMI electromagnetic interference events 3M ESD Pro employs a patent pending system that analyzes wav...

Page 4: ...agnostics and troubleshooting ESD tool qualification EMI diagnostics and more The 3M ESD Pro detects ESD events by the specific electromagnetic signature these events produce As such the performance o...

Page 5: ...placement on any conductive or even dissipative surface When working with the automated equipment always observe safety precations as recommended by equipment manufacturer and your company s practices...

Page 6: ...strength is a factor of many variables the accumulated static voltage the capacitance of the charged objects a larger object holds more charge than a smaller one the physical size of discharging obje...

Page 7: ...aph will show it in red An event below this level will still be shown on the bar graph in green but no count or sound will be produced Setting the Threshold To set a new threshold do not press the swi...

Page 8: ...ttery Compartment on the back Controls and Indicators Power Switch Turns power on and off Sound Switch Turns the sound on and off CDM Turns EMI rejection mode on and off Alarm Threshold Adjusts alarm...

Page 9: ...re and how many of them occur Thus instruments such as the 3M ESD Pro serve as your ultimate measure of effectiveness of your ESD protection The 3M ESD Pro is capable of rejecting non ESD related EMI...

Page 10: ...battery to the battery clips Observe the polarity of the battery Re install the battery door Low Battery Indicator When battery voltage gets low less than 20 capacity remains the low battery indicato...

Page 11: ...can produce audible alarm when an event is deleted In order to enable this function move the actuator of sound slide switch to the right The Next Step If you want to further your knowledge of strengt...

Page 12: ...or part does contain a substance as detailed in the chart below in excess of the following maximum concentration values in any homogeneous material a 0 1 by weight for lead mercury hexavalent chromium...

Page 13: ...thin a reasonable time after written notification of said non conformance and return of said product to 3M 3M shall not under any circumstances be liable for direct incidental special or consequential...

Page 14: ...tor Battery snap connector Solder in instrument IC Solder in IC Solder in buzzer SJ T11363 2006 Indicates that this hazardous substance contained in all of the homogeneous materials for this part is b...

Page 15: ...15...

Page 16: ...hase order shall have no force or effect unless expressly agreed upon in writing by an authorized officer of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in mate...

Reviews: