3M ECAM-27MM-D Instructions Manual Download Page 17

17

78-8140-2401-0-B

Note:  If installing the metallic version, some of the larger diameter cables with large strength members it may be 

necessary to remove the retainer screw from the cable strength member (CSM) clamps in order to install 

the double external cable assembly module (ECAM) into the port. Reinstall the CSM screws and vinyl caps 

after installing the double ECAM assembly into the closure base. 

12.4  Loosen the clamps and position over double 

cable assembly ECAM assembly as shown at 

right. Torque screw to 45 in.-lbs.

13.0 Ground Wire Installation

13.1 

Metallic Version: 

Please refer to Instruction Manual 78-8128-0289-6-C 

3M

 Scotchlok Shield Bond 

Connector Assembly 4460-D\FO 

for ground wire installation.

13.2 

Non-Metallic Isolated version: 

Please refer to Instruction Manual 78-8128-0289-6-C 

3M

 Scotchlok 

Shield Bond Connector Assembly 4460-D\FO-SS 

for ground wire installation.

14.0 3M

 Double Cable Entry Port ECAM-27MM-D Accessories

UPC Number

Description

3M I.D. Number

00051115191961

3M

 Grounding Kit (6 AWG)

80-6113-1702-7

00051115191985

3M

 Grounding Kit (14 AWG)

80-6113-1704-3

05400792757

Scotchlok

 Shield Bond Connector Assembly

80-6108-4444-3

Scotchlok

 Shield Bond Connector Assembly

80-6113-8269-0

Summary of Contents for ECAM-27MM-D

Page 1: ...July 2011 78 8140 2401 0 B 3M Double Cable Entry Port ECAM 27MM D 3M Double Cable Entry Port ECAM 27MM ACT Instructions 3...

Page 2: ...ontents 2 1 Metallic Version A B L C O J E H K I D G F N M P A Mastic tape rolls 2 B Oval gasket C Sheath scuff D Silicone lubricant E Cable clamp shells 4 sets F Vinyl caps 2 G Alcohol wipe H Cable c...

Page 3: ...d wire 4 H Washers set 1 set shown 4 sets I Cable ties J Cable gauge decal K Mastic rope L Housing bottom half M Housing top half w 3 mtg Screws N 3M Scotchlok Shield Bond Connector 4460 D FO SS loose...

Page 4: ...ABLE PREP 6 150 mm TRIM SINGLE OR DUAL CSM RODS 8 200 mm CENTRAL TUBE TRIMMED EXPRESS LOOSE BUFFER TUBE CABLE EXPRESS CENTRAL TUBE CABLE BRANCH OR DROP CABLE Armored Cable Central Strength Member 6 15...

Page 5: ...otch All Weather Telephone Vinyl Plastic Tape 88T or equivalent to protect fiber from the sharp cable sheath edges Do not wrap the last inch 25 mm of the cable sheath 4 3 Prepare the closure base by l...

Page 6: ...5 0 3M Double Cable Assembly ECAM 27MM D Removal 5 1 Using a 3 8 inch 10 mm nut driver loosen the clamp screws on the external cable assembly module ECAM Pull clamps outward and rotate as shown Lightl...

Page 7: ...e Cable Entry Port ECAM 27MM D This information can be recorded in the log at the bottom of this page Note If the arrows on the decal point at the line between two different sizes use what is listed i...

Page 8: ...ed clamp shell sets from part tree Make two sets of clamp shells for each cable 7 2 If multiple shells are required for a specific cable size locate these and assemble into sets 7 3 Note the orientati...

Page 9: ...dirt Note Carefully follow health safety and environmental instructions as given on Material Safety Data Sheet for the alcohol wipe Scuff the first 3 of each cable sheath using the supplied sheath scu...

Page 10: ...collar 8 4 Washers can be split along notch for installation over the cable 8 5 Install two washers on each cable near sheath end as shown 8 6 Unroll mastic and measure out the required amount Repeat...

Page 11: ...mm from the sheath end Wrap mastic evenly around cable DO NOT STRETCH MASTIC 8 9 Release liner can be wrapped around mastic collar temporarily to keep mastic clean Be sure to remove the liner before i...

Page 12: ...assembly module ECAM housing bottom half Note the grooves in the housing for locating washers Note If differently sized cables are used ensure the cable is placed into the correct cable clamp shell se...

Page 13: ...and lightly tighten Evenly tighten the two outer screws shorter screws along with the center screw by alternating between Torque all three clamp screws to 30 in lbs 8 15 Place top half of the 3M Doub...

Page 14: ...torque 8 18 Trim excess mastic using snips or knife Note Do not cut flush or pull out rope mastic Leave 1 8 inch 4mm of the ends of the rope mastic protruding 8 19 Press mastic flat using a finger ti...

Page 15: ...coded cable ties can be installed at this time to attach caps and can also be used to identify feeder or distribution cables 10 0 Cable Strength Member Installation For armored loose tube cable 10 1 P...

Page 16: ...Lightly lubricate the oval gasket using the supplied silicone lubricant before installing the gasket into the groove in the base of the 3M Fiber Dome Note Follow health safety and environmental infor...

Page 17: ...crew to 45 in lbs 13 0 Ground Wire Installation 13 1 Metallic Version Please refer to Instruction Manual 78 8128 0289 6 C 3M Scotchlok Shield Bond Connector Assembly 4460 D FO for ground wire installa...

Page 18: ...arranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING...

Reviews: