78-8130-6151-8-E
31
5. Adjust the
Gain Down
[4] until the bar graphs open.
− The bar graph will close, the audio will increase, and the signal strength will be
maximum when the receiver detects a marker of the specified utility.
− When one of the two markers is detected, press the
“XXX Only”
[SK] for the
detected utility marker.
− The unit will switch to Single Marker Locate in order to pinpoint the marker.
6. Press
Markr 2
[SK Toggle] to return to Dual Marker Locate.
Marker Depth Estimate
ID Marker Depth
1. Lower the tip of the receiver to the ground over the targeted marker.
2. Press
Depth
[SK].
− The receiver will examine the marker
(Calculating, please wait...)
− If the marker is a 3M
™
Dynatel
™
iD
Marker, the receiver will display the
depth of the marker, and its identification
number.
3. To save the depth reading, press
Mem Select
[SK].
− Five depth readings can be saved with the
time, date, and its identification number.
− Save [SK] will place each entry in
sequential order in memory (M1 - M5)
until five readings have been stored. The
unit will overwrite saved entries in excess
of five, beginning with M1.
4. Press
Clear All
[SK] to delete all stored depth information.
5. Press
Mem Select
[SK] to select the memory location to store the depth readings.
When the preferred location appears on the screen, press
Save
[SK]. The screen and
memory location will populate with the current information.
6. Each memory location can be reviewed by pressing
Mem Select
[SK].
7. Press
Locate
[5] to return to Marker Locate Mode.