Chapter 3: Maintaining the monitor
33
5.
While gently pressing the fuse holder, turn the screwdriver
counterclockwise
.
The fuse holder will pop out of the ET 350 monitor.
6.
Remove the fuse holder with the fuse.
7.
Detach the fuse from the fuse holder by pulling on it gently.
Figure 12: Removing fuse from fuse holder
8.
Replace the fuse. For fuse specifications, see “Fuses” on page 52.
9.
Reinstall the fuse holder in the ET 350 monitor.
10.
While gently pressing the fuse holder, turn the screwdriver clockwise.
11. If the monitor has a hatch
, close the hatch cover (opened earlier):
Insert all screws loosely. Using a No. 1 Phillips torque screwdriver,
gradually tighten diagonal pairs of screws until all are equally tight at
a torque of 7 inch-pounds. This may require about three rounds of
tightening.
12.
Re-connect power to the unit.
Checking gaskets
Follow these guidelines to check and clean the gaskets on your monitor:
Make sure there is no debris on gaskets that will prevent a seal.
If debris needs to be cleaned from gaskets, do so gently.
If gaskets are torn or damaged, return to 3M Touch Systems for
servicing.
Warning
To reduce the risk of fire or electric shock which could result in serious personal
injury or death, when replacing a fuse or other part, use a part of the same type
rating specified by 3M Touch Systems.
Summary of Contents for Dynapro ET 350 Monitor
Page 6: ......
Page 10: ......
Page 14: ......
Page 18: ......
Page 22: ......
Page 26: ......
Page 29: ...xxvii 5BCDEF ET 350 GH GH GH GH IJ IJ IJ IJ KL KL KL KL MNOPQRS TU TU TU TU ...
Page 30: ......
Page 32: ......
Page 34: ......
Page 38: ......
Page 64: ......
Page 82: ......
Page 90: ......
Page 96: ......