Brightness-Enhanced Display and Moisture Deflector Options

Page 2

n

Do not attempt to repair the Moisture Deflector 
yourself. Doing so will void the warranty. 
If cracks develop in the Moisture Deflector or if it 
breaks, contact 3M Touch Systems (see 
“Contacting 3M Touch Systems‚” on page 3)

n

Do not allow dirt or debris to build up on the 
Moisture Deflector.

Mounting the ET 3250/3255 with 

Moisture Deflector

The ET 3250/3255 with Moisture Deflector must be 
mounted vertically. There must be no more than 10 
degrees variance from vertical for the Moisture 
Deflector to operate.

As long as this 10 degree rule is observed, it is 
possible to mount the ET 3250/3255 with the 
Moisture Deflector in any of the ways described in the 

Getting Started Guide

 and 

User’s Guide

 (see 

“Related documents‚” on page 3).

Opening the enclosure of 

ET 3250/3255 with Moisture 

Deflector

To open the enclosure of ET 3250/3255 Computers 
(for a task such as adding an expansion card or 
replacing a TouchSurround underlay) follow these 
steps:

1.

Put on a grounding strap and touch a grounded 
object to discharge any built-up static.

2.

Look on the back of the bezel for four security 
screws and remove them with the appropriate 
screwdriver.

3.

Find the latch screw on the top of the enclosure 
and use an Allen key or a flat-blade screwdriver 
to turn the screw ¼ turn counter-clockwise, or 
until you feel the enclosure open.

4.

Place the computer face down on the work bench 
and open the main enclosure as far as it will go.

5.

Have one person support the enclosure in the 
open position. Follow the instructions in the 

User’s Guide

 (see “Related documents‚” on 

page 3) to complete your task.

6.

When your task is finished, close the bezel 
assembly, lock the latch screw, and replace the 
four security screws. Tighten the screws to a 
torque of 10 inch-pounds.

Standards and certifications

The ET 3250/3255 with Moisture Deflector and the 
ET 3250/3255 with BE Display meet the following 
specifications and standards.

Enclosure

Display

Non-operating conditions

The equipment meets these non-operating conditions:

Dimensions

Imperial

16.30" wide

14.00" high

6.60" deep

Metric

414.0 mm wide

 355.6 mm high

167.6 mm deep

Weight

Imperial

25.0 lb.

Metric

11.4 kg

Material

Die cast aluminum

Viewing area (diagonal)

15.0"

Resolution

1024 × 768 XGA

Type

Active color TFT

Panel colors (up to)

65,536

Backlights

Two cold cathode 
fluorescent tubes (CCFT)

Backlight life 
expectancy

50,000 hr

Brightness (typical)

340 cd/m

2

Condition

Range

Shock

Acceleration: 30 G

Pulse duration: 11 ms

Vibration

5–57 Hz: 0.015" (0.38 mm)
peak displacement

58–2000 Hz: 
2.5 G acceleration

Storage 
temperature

-13°–140°F (-25°–60°C)

Maximum 
storage altitude

40,000 feet (12 192 meters)

Summary of Contents for Dynapro ET 3250

Page 1: ...igh ambient light e g brightly lit workplaces Handling and maintaining the Moisture Deflector The Moisture Deflector is made of durable plastic and like other 3M Dynapro components is designed to function in rugged conditions The Moisture Deflector is not indestructible however Here are a few guidelines to extend its life and help ensure optimal performance n Before starting the unit make sure tha...

Page 2: ...top of the enclosure and use an Allen key or a flat blade screwdriver to turn the screw turn counter clockwise or until you feel the enclosure open 4 Place the computer face down on the work bench and open the main enclosure as far as it will go 5 Have one person support the enclosure in the open position Follow the instructions in the User s Guide see Related documents on page 3 to complete your ...

Page 3: ...e 6 560 feet 2 000 m 6 560 feet 2 000 m UL 50 1992 Enclosures for Electrical Equipment enclosure 4X enclosure 12 NEMA 250 Electrical Enclosures Type 4X Type 12 CSA C22 2 No 94 M91 Special Purpose Enclosures enclosure 4X enclosure 12 IEC 529 Protection of Equipment IP66 UL 1950 1995 For Information Technology Equipment UL 3121 For Process Control Equipment CSA C22 2 No 950 1995 For Information Tech...

Page 4: ...3M 2001 3M Touch Systems 3M Optical Systems Division 800 Carleton Court Annacis Island New Westminster BC Canada V3M 6L3 Tel 604 521 3962 Toll free 1 800 667 0374 Fax 604 521 4629 E mail touch mmm com www 3Mtouch com ...

Reviews: