background image

IMPORTANT NOTES

 

• Failure to follow instructions may void warranty.

  • Allow a minimum of 3” (7.6 cm) clear space under filter to facilitate cartridge change.
  • Install with the inlet and outlet ports as labeled.  Make sure not to reverse connections.
  • Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable 

water line.

CAUTION

To reduce the risk associated with property damage due to water leakage:
  • Read and follow 

Use Instructions before installation and use of this system.

  • Installation and Use 

MUST

 comply with all state and local plumbing codes.

  • 

Protect from freezing, 

remove filter cartridge when temperatures are expected to drop

 

below 40°F (4.4°C);

 

• Do not install 

on hot water supply lines. The maximum operating water temperature of this filter system is 

100°F (37.8°C).

  • 

Do not

 

install

 if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa),   

       you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check 

 your water pressure.

  • 

Do not

 

install

 where water hammer conditions may occur. If water hammer conditions exist, you must

       install a water hammer arrester.  Contact a plumbing professional if you are uncertain how to check for this 

condition.

  • 

Do not

 use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic  

       plumbing.
  • On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape 

only

, pipe dope properties may

       deteriorate plastic.
  • Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtight--

       ening occurs.

 

• 

Do not 

install in direct sunlight or outdoors.

  • 

Do not

 install near water pipes which will be in path of a drilling tool when selecting the position to mount 

       the bracket.
  • Mount filter in such a position as to prevent it from being struck by other items used in the area of installation.
  • Ensure that the location and fasteners will support the weight of the system when installed.
  • Ensure all tubing and fittings are secure and free of leaks.
  • The disposable filter cartridge 

MUST

 be replaced every 12 months or at the rated capacity or if a noticeable   

        reduction in flow rate occurs.

    • 

Any non-metallic fittings used in the installations must be of adequate rating for the line pressure.

3

DP Manifolds and Systems

  The DP High Flow Series Water Filtration Systems help provide consistent high quality water for multiple    
  applications of cold beverages, ice, and coffee. The inlet water enters the manifolds on the left rear side and flows  
  through 1, 2, or 3 cartridge filters in parallel (depending upon which manifold is installed).  Two separate streams  
  exit the manifold. One stream (on the right front side) has scale-inhibition media added from a dedicated cartridge  
  to reduce the ability of calcium and magnesium to precipitate as hard scale in ice machines and coffee brewers.  
  The other stream exits on the left side front.  It supplies cold beverage dispensers and includes no scale inhibitor.   
  The  capacity of the system is equal to the total combined flow rate and capacity ratings for the number of  

Summary of Contents for DP1XX

Page 1: ...r Please leave this manual with owner operator Dual Port Manifold Water Filtration Systems Instruction Manual 1 For DP1XX DP2XX and DP3XX High Flow Series Water Filtration Systems 3M Water Filtration...

Page 2: ...ion which if not avoided could result in death or seri ous injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moder ate injur...

Page 3: ...only pipe dope properties may deteriorate plastic Take care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if overtight ening occurs Do not install in direct sunli...

Page 4: ...Remove Cartridge 3 in 7 6 cm Minimum 29 5 16 74 5 cm 5 7 16 13 8 cm HF9X Series Cartridge 24 1 16 61 1 cm HF6X Series Cartridge 18 1 16 45 9 cm HF4X Series Cartridge 15 1 16 38 3 cm DP2XX Water Filtra...

Page 5: ...dow How to Use the Inlet Outlet Fitting Retention Clips CAUTION To reduce the risk associated with property damage due to water leakage Do not use a torch or other high temperature sources near filter...

Page 6: ...es and apply a light coat of water or food grade lubricant to the o rings on each of the cartridges 7 Align the tabs of the cartridge with the slots in the retaining plate and insert the cartridge int...

Page 7: ...cartridge is removed 6 Remove sanitary cap from new cartridge Install water filter cartridge with a quarter turn to the right until cartridge comes to a complete stop Repeat for remaining filter cartr...

Page 8: ...25005 Inlet fitting kit left rear 1 Inlet fitting with ball valve 7 6225006 Outlet fitting kit left front 1 Beverage outlet fitting 8 6225007 Outlet fitting kit right front 1 Ice Coffee outlet fitting...

Page 9: ...utlet fittings 7 6225005 Inlet fitting kit left rear 1 Inlet fitting with ball valve 8 6225006 Outlet fitting kit left front 1 Beverage outlet fitting 9 6225007 Outlet fitting kit right front 1 Ice Co...

Page 10: ...4 8500549 Pressure gauge 1 Monitor outlet water pressure 5 85 8528 Clip 1 Retain inlet outlet fittings 6 63597320 o ring 1 Seal inlet outlet fittings 7 6225005 Inlet fitting kit left rear 1 Inlet fitt...

Page 11: ...fective equipment or part which having been returned to the factory transportation charges prepaid has been inspected and determined by the Seller to be defective THIS WARRANTY IS IN LIEU OF ANY OTHER...

Page 12: ...M and CUNO are trademarks of 3M Company used under license INSTR4325 1008 CUNO Incorporated a 3M Company 400 Research Parkway Meriden CT 06450 USA Toll Free 1 888 218 CUNO Worldwide 203 237 5541 Fax 2...

Reviews: