Summary of Contents for DBI SALA 2100090

Page 1: ... 3M 2020 USER INSTRUCTIONS 5902381 Rev D PERIMETER LIMITER Counterweight Fall Arrest System 1 2100090 OSHA 1926 502 OSHA 1910 140 ...

Page 2: ......

Page 3: ...3 2 C A B D G F E H I 3 4 C B A FC B C FC ...

Page 4: ...4 5 6 A B C A B C D E F G 7 8 45 45 45 ...

Page 5: ...5 9 A B C D 10 A B D C ...

Page 6: ...6 11 B D A F E ...

Page 7: ...20XX 20__ 20__ 20__ 20__ 20__ 20__ 20__ 20__ 20__ XX XX ABC 20__ C E B 8525185 Rev D 310 lbs 140 kg 310 lbs 140 kg 1 350 lb 6 kN MAF 900 lb 4 kN AAF OSHA 1926 502 1910 140 2 0 61m 24 7 31m 3 0 91m 26 7 92m D F ...

Page 8: ...ems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems TIE OFF ADAPTERS Ensure the tie off adapter device is tight against the anchoring structure Never leave sla...

Page 9: ...yards etc used with the Perimeter Limiter must limit Arresting Force to the following values as determined by the applicable standard Applicable Standards Maximum Arresting Force Average Arresting Force OSHA 1 350 lbf 6 0 kN 900 lbf 4 0 kN Dimensions See Figure 7 Product Weight 2 015 lb 914 kg Standards Meets the test requirements of OSHA 1926 502 and 1910 140 Component Specifications Figure 2 Ref...

Page 10: ...es or overhead materials that may fall and contact the user or Personal Fall Arrest System 2 5 FALL CLEARANCE Figure 4 illustrates the components of a Fall Arrest There must be sufficient Fall Clearance FC to arrest a fall before the user strikes the ground or other obstruction Clearance is affected by a number of factors including Anchorage Location A Lanyard Length B Lanyard Deceleration Distanc...

Page 11: ...unless the snap hook complies is equipped with a 3 600 lb 16 kN gate Check the marking on your snap hook to verify that it is appropriate for your application C In a false engagement where features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmation seems to be fully engaged to the anchor point D To each other E Directly to webbing or rope lanyard or t...

Page 12: ...Fall Arrest System PFAS meet all criteria defined in Section 2 and a formal Rescue Plan is in place Inspect the Perimeter Limiter per the User inspection points defined on the Inspection and Maintenance Log Table 2 If inspection reveals an unsafe or defective condition do not use the system Remove the system from service and destroy or contact 3M regarding replacement or repair 4 2 FALL ARREST CON...

Page 13: ...fective conditions remove the system from service and contact 3M regarding replacement or repair 6 3 STORAGE AND TRANSPORT When not in use store and transport the Fixed Beam Anchor and associated fall protection equipment in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors may exist Thoroughly inspect components after extended storage 7 0 LABELS Figure 11 illus...

Page 14: ...orrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date...

Page 15: ......

Page 16: ...m WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC GLOBAL PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Unless otherwise provided by lo...