3M DBI SALA 1340005 User Instructions Download Page 14

14

 

;

Before using this equipment, record the product identification information from the ID label in the ‘Inspection and 

Maintenance Log’ at the back of this manual.

 

;

Always ensure you are using the latest revision of your 3M instruction manual. Visit the 3M website or contact 3M 

Technical Services for updated instruction manuals.

PRODUCT DESCRIPTION:

Figure 1 lists the 3M™ DBI-SALA

®

 Pro Series Lanyards covered by this instruction manual. Lanyards covered in this instruction 

may be used for Restraint or Work Positioning applications. Energy-Absorbing Lanyards may be used for Fall Arrest applications 

as well.
Lanyards are web or cable tethers with connectors on either end. Connectors wil vary per model, as will the presence of an 

energy absorber. Only Energy-Absorbing Lanyards will include energy absorbers for Fall Arrest.
One end of the lanyard will secure to the designated attachment element on the user’s harness, while the other end secures to 

anchorage connection point or anchorage structure. For Energy-Absorbing Lanyards, the end with the energy absorber should 

always connect to the user’s harness. Twin Leg Lanyard models provide 100-percent tie-off while moving from point to point. 

See Table 1 for Lanyard and Connector specifications.

 

;

Only specific models covered by this instruction include energy absorbers. See Table 1 for more information. Only lanyard 

models that include an integral energy absorber should be used for Fall Arrest applications. All other models are limited to 

Restraint or Work Positioning applications and should not be used to arrest a fall.

Table 1  – 

Specifications

Lanyard Specifications:

Figure 1 

Reference

Description

Material

Energy Absorber

ANSI Standard 

Certification

1

Protecta Energy-Absorbing Lanyard

Web - Polyester

Shock Pack

ANSI Z359.13

2

Protecta Energy-Absorbing Lanyard 100% Tie-Off

Web - Polyester

Shock Pack

ANSI Z359.13

3

Protecta Lanyard

Web - Polyester

---

ANSI Z359.3

4

Protecta Adjustable Lanyard

Web - Polyester

---

ANSI Z359.3

5

Protecta Energy-Absorbing Lanyard

Web - Elastic Polyester

Tubular Web

ANSI Z359.13

6

Protecta Energy-Absorbing Lanyard 100% Tie-Off

Web - Elastic Polyester

Tubular Web

ANSI Z359.13

7

Protecta Lanyard

Web - Polyester

Shock Pack

ANSI Z359.13

8

Protecta Lanyard with Rope Grab

Web - Polyester

Shock Pack

ANSI Z359.13

9

Protecta Energy-Absorbing Lanyard

Cable - Galvanized

Shock Pack

ANSI Z359.13

10

Protecta Energy-Absorbing Lanyard 100% Tie-Off

Cable - Galvanized

Shock Pack

ANSI Z359.13

11

Protecta Lanyard

Nylon Rope

---

ANSI Z359.3

12

Protecta Energy-Absorbing Lanyard 100% Tie-Off

Nylon Rope

Shock Pack

ANSI Z359.13

13

Protecta Rebar Assembly

Zinc-Plated Steel Chain

---

ANSI Z359.3

14

Protecta Rebar Assembly

Web - Polyester

---

ANSI Z359.3

Connector Specifications:

Figure 1 

Reference

Model Number

Description

Material

Gate Opening

Gate Strength

Tensile Strength

A

2000161

Snap Hook

Zinc-Plated Steel

3/4 in. (19 mm)

3,600 lbf (16 kN)

5,000 lbf (22.2 kN)

B

9502573

Snap Hook

Zinc-Plated Steel

2-3/8 in. (60 mm)

3,600 lbf (16 kN)

5,000 lbf (22.2 kN)

C

2000164

Rebar Hook

Alloy Steel

2-3/8 in. (60 mm)

3,600 lbf (16 kN)

5,000 lbf (22.2 kN)

D

9501908

Rope Grab

Steel

E

1300021

Rope Grab

Steel

F

9504413

Carabiner

Zinc-Plated Steel

1-1/8 in. (28.6 mm)

5,000 lbf (22.2 kN)

5,000 lbf (22.2 kN)

G

9000047

D-Ring

Alloy Steel

Performance Specifications:

Capacity:

One person with a combined weight (including clothing, tools, etc.) within the range of 130 lb. to 310 lb.  

(59 kg to 140 kg).

Average Arresting Force:

900 lbf (4.0 kN)

Maximum Free Fall:

6.0 ft. (1.83 m)

Summary of Contents for DBI SALA 1340005

Page 1: ...050 1 6 0 ft 1 83 m 1 75 in 4 45 cm 1 1 1341051 1 6 0 ft 1 83 m 1 75 in 4 45 cm 1 2 L W Y Y X 1 1340060 2 6 0 ft 1 83 m 1 75 in 4 45 cm 1 1 1340180 2 6 0 ft 1 83 m 1 95 in 4 95 cm 2 1 1340181 2 5 0 ft 1 52 m 1 95 in 4 95 cm 2 1 1340182 2 4 0 ft 1 22 m 1 95 in 4 95 cm 2 1 1340183 2 10 0 ft 3 05 m 1 95 in 4 95 cm 2 1 1340187 2 6 0 ft 1 83 m 1 95 in 4 95 cm 2 1 1342001 2 6 0 ft 1 83 m 1 95 in 4 95 cm...

Page 2: ...cm 1 1 1340230 5 6 0 ft 1 83 m 1 3 8 in 3 49 cm 1 1340270 5 4 0 ft 1 22 m 1 15 16 in 4 92 cm 1 1 1341101 5 6 0 ft 1 83 m 1 75 in 4 45 cm 1 1 1341102 5 4 0 ft 1 22 m 1 75 in 4 45 cm 1 1 1341125 5 6 0 ft 1 83 m 1 75 in 4 45 cm 1 6 L W X Y Y 1 1340141 6 6 0 ft 1 83 m 1 15 16 in 4 92 cm 2 1 1340161 6 6 0 ft 1 83 m 1 15 16 in 4 92 cm 2 1 1340240 6 6 0 ft 1 83 m 1 3 8 in 3 49 cm 2 1 1340250 6 6 0 ft 1 8...

Page 3: ...8 2 17 ft 0 66 m 1 75 in 4 45 cm 1 1 1340005 8 2 17 ft 0 66 m 1 75 in 4 45 cm 1 9 L W X Y 1 1340401 9 6 0 ft 1 83 m 1 4 in 0 64 cm 1 10 L W X Y Y 1 1340451 10 6 0 ft 1 83 m 1 4 in 0 64 cm 2 1 1340452 10 6 0 ft 1 83 m 1 4 in 0 64 cm 2 11 L W X Y 1 1385501 11 6 0 ft 1 83 m 1 2 in 1 27 cm 1 12 L W X Y Y 1 1340751 12 6 0 ft 1 83 m 1 2 in 1 27 cm 2 A B C D E F G ...

Page 4: ... L W X Y Y 1 1350150 13 2 0 ft 0 61 m in cm 2 1 1350200 13 1 67 ft 0 51 m in cm 2 14 L W X Y Y 1 1351001 14 1 83 ft 0 56 m 1 0 in 2 54 cm 2 1 1351050 14 1 83 ft 0 56 m 1 0 in 2 54 cm 2 1 1351051 14 1 5 ft 0 46 m 1 0 in 2 54 cm 2 A B C D E F G ...

Page 5: ...5 2 3 A F A H H A F B F H A F A H 4 FC A B C M H SF M A B C H SF FC ...

Page 6: ...User Weight B 220 lb User Weight C 310 lb User Weight D Maximum Allowable Deployment Distance OSHA E Maximum Allowable Deployment Distance ANSI F Maximum Allowable Free Fall OSHA ANSI A B C E D F Free Fall Distance Feet Deployment Distance Feet ProStop Personal Energy Absorbers 6 7 A B C D E F G A B C ...

Page 7: ...7 8 A B C 9 1 2 3 10 11 1 A 2 B A 2 1 3 B ...

Page 8: ...8 12 A ü B ü C D 13 14 A B C 15 A A A B A B C ...

Page 9: ...9 16 17 18 A B C D D C B A 19 C C B A D E ...

Page 10: ...r more information Failure to heed instructions and warnings may result in serious injury or death Do not remove this label NO Arrest force 1800 lbs 816 5 kg when rigged as shown A DO NOT REMOVE THIS LABEL IN SERIOUS INJURY OR DEATH TO HEED THIS WARNING MAY RESULT CAUSING RELEASE OF LOAD FAILURE MAY BE FORCED OPEN UNDER LOADING ANCHORAGE MEMBER SNAP HOOK GATE DO NOT ALLOW SNAP HOOK TO CONTACT WARN...

Page 11: ...INIMUM SERVICETEMP 40 F 40 C K L N O M P J AE57610 P 1385301 E 1340121 C F 1340130 D AC202A10 J N AE57630 P 1340220 C F 1340260 D 1340005 D 1340060 A B D 1340230 C F 1340401 D 1340040 B D 1340180 A I M O 1340270 C F 1340451 A D 1340125 I M 1340181 A I M O 1341101 D 1340452 A D 1340200 B D 1340182 A I M O 1341102 D 1385501 G H L 1341001 I M 1340183 A I M O 1341125 D 1340751 A D 1341002 I M 1340187 ...

Page 12: ...ed from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems To reduce the risks associated with working at height which if not avoided could result in serious injury or death Ens...

Page 13: ...t with sharp edges or corners Ensure the device is rigged appropriately for the intended use Attach the unused leg s of the lanyard to the parking attachment s of the harness if equipped Do not tie or knot the lanyard Do not exceed the number of allowable users Ensure that fall protection systems subsystems assembled from components made by different manufacturers are compatible and meet the requi...

Page 14: ...ference Description Material Energy Absorber ANSI Standard Certification 1 Protecta Energy Absorbing Lanyard Web Polyester Shock Pack ANSI Z359 13 2 Protecta Energy Absorbing Lanyard 100 Tie Off Web Polyester Shock Pack ANSI Z359 13 3 Protecta Lanyard Web Polyester ANSI Z359 3 4 Protecta Adjustable Lanyard Web Polyester ANSI Z359 3 5 Protecta Energy Absorbing Lanyard Web Elastic Polyester Tubular ...

Page 15: ...mine the Deployment Distance of that graph line by reading the Y axis Deployment Distance and Free Fall Distance should never exceed the limits of your applicable standard see below If your weight falls between the user weights displayed on the graph refer to the higher of the two lines when determining Deployment Distance Figure 5 Reference Description A 130 lb User Weight B 220 lb User Weight C ...

Page 16: ...10 140 Anchorages used for attachment of personal fall arrest systems shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5 000 lbf per user attached or be designed installed and used as part of a complete personal fall arrest systems which maintains a safety factor of at least two and is under the supervision of a qualified person Fr...

Page 17: ...opardize compatibility of equipment and may affect safety and reliability of the complete system 2 5 COMPATIBILITY OF CONNECTORS Connectors are compatible with connecting elements when the size and shape of either component does not cause the connector to inadvertently open regardless of orientation Connectors must comply with applicable standards Connectors must be fully closed and locked during ...

Page 18: ...ions exist where connection to an SRD may be permissible Contact 3M Technical Services with any questions or concerns 3 4 LANYARD ADJUSTMENT Some Lanyard models are equipped with an Adjuster to shorten or lengthen the Lanyard Leg s and eliminate Lanyard slack Keeping the Lanyard taut reduces the chance of tripping on the Lanyard or snagging the Lanyard on surrounding objects Buckle Adjuster Figure...

Page 19: ...spection should be maintained by the owner of this equipment An inspection and maintenance log should be placed near the product or be otherwise easily accessible to users It is recommended that the product is marked with the date of next or last inspection 5 3 DEFECTS If the product cannot be returned to service because of an existing defect or unsafe condition then it must be destroyed 5 4 PRODU...

Page 20: ...ire rope is the length of wire rope it takes for a strand the larger groups of wires to complete one revolution or twist along the rope Replace the wire rope assembly if there are any broken wires within 1 inch 25 mm of the ferrules Energy Absorber Figure 19 Verify that the integral Energy Absorber has not been activated An open cover A or torn cover B webbing pulled out of the cover C torn or fra...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...m WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC GLOBAL PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Unless otherwise provided by lo...

Reviews: