SECTION 7: SPECIFICATION AND OPERATING DATA
ITEM
APIF100
APIF100J
APIF100M
APIF100PT
APIF100MPT
APIF100MJ
APIF150
APIF150J
APIF150M
APIF150PT
APIF150MPT
APIF150MJ
APIF200
APIF200J
APIF200M
APIF200PT
APIF200MPT
APIF200MJ
APIF300
APIF300J
APIF300M
APIF300PT
APIF300MPT
APIF300MJ
Media Volume, cu. ft. (cu. mtr.) (Note 1):
Gravel Underbed, lbs. (kg)
Nominal Capacity, ppm-gal.
Operating Flow Rate, gpm (lpm) (Note 2):
Continuous
Service
Pressure Loss @ Flow Rates, psi (kPa)
Continuous
Service
Backwash Flow Rate, gpm (lpm) Note 3
Service Pipe Size, in. (cm) (Note 4)
Filter Tank Diameter x Height, in. (cm)
Minimum Space Required, in. (cm):
Width
Depth (w/Bypass)
Height
Approximate Shipping Weight, lbs. (kg)
1.0 (0.03)
13 (5.9)
30,000
3 (11.4)
6 (22.7)
2 (13.8)
5 (34.5)
5.3 (20.1)
1 (2.5)
10 x 44
(26 x 112)
12 (30)
16 (41)
53 (135)
143 (64.9)
1.5 (0.04)
13 (5.9)
45,000
3 (11.4)
7 (26.5)
2 (13.8)
7 (48.2)
5.3 (20.1)
1 (2.5)
10 x 54
(26 x 137)
12 (30)
16 (41)
63 (160)
186 (84.4)
2.0 (0.06)
18 (8.2)
60,000
4 (15.1)
9 (34.1)
2 (13.8)
8 (55.1)
7.5 (28.4)
1 (2.5)
12 x 54
(30 x 137)
12 (30)
16 (41)
63 (160)
257 (116.6)
3.0 (0.08)
26 (11.8)
90,000
5 (18.9)
12 (45.5)
2 (13.8)
10 (68.9)
10 (37.9)
1 (2.5)
14 x 65
(36 x 165)
13 (33)
16 (41)
74 (188)
353 (160.2)
Maximum Operating Temperature 110°F (43.3°C); Electrical requirements 110V/60Hz; Operating Pressure 20 -100 psi (138-689
kPa). Specifi cations subject to change without notice.
7-2
IMPORTANT NOTE
1) Replenishment of pH adjusting component of media may be required periodically, the frequency of which is dependent on raw water pH,
manganese concentration and water consumption rate. Consult dealer for more information.
2) For satisfactory performance, indicated durations should not be exceeded. Flow rates specifi ed are adequate for normal residential applica-
tions. Do not use Service or Peak fl ow rates when sizing commercial applications or if treated water is to supply a geothermal heat pump,
swimming pool, etc. (contact dealer before selecting equipment). Service fl ow rates have been tested against NSF Standard 42 and have a
rated pressure drop of less than 10 psi.
3) For system to operate properly, pumping rate of well pump MUST be suffi cient to backwash unit at rate specifi ed.