background image

Surgical Clipper with Fixed Head
Tondeuse chirurgicale à tête fixe
Medizinisches rasiergerät mit feststehendem scherkopf
Rasoio chirurgico ricaricabile clipper con testina fissa
Rasuradora quirúrgica con cabezal fijo
Chirurgische clipper met vaste kop
Kirurgisk klippapparat med fast huvud
Kirurgisk klipper med fast hoved
Kirurgisk clipper
Kkirurgiset karvanleikkurit kiinteällä päällä
Máquina eléctrica de tricotomia com cabeça fixa

ÃÂÈÚÔ˘ÚÁÈ΋ •˘ÚÈÛÙÈ΋ ªË¯·Ó‹Ì ™Ù·ıÂÚ‹

§

ÂÊ·Ï‹

9671

3

Clipper: Made in USA from Foreign and US Components
for

3M Health Care

, St. Paul, MN  55144-1000

Charger: Made in China for 

3M Health Care

,

St. Paul, MN  55144-1000
Blade Assembly: Made in USA for 

3M Health Care

,

St. Paul, MN  55144-1000

3M Health Care

D-41453 Neuss, Germany

3M is a trademark of 3M
© 3M 2004 All rights reserved.

34-7057-8706-6

Summary of Contents for 9671

Page 1: ...ipper med fast hoved Kirurgisk clipper Kkirurgiset karvanleikkurit kiinteällä päällä Máquina eléctrica de tricotomia com cabeça fixa ÃÂÈÚÔ ÚÁÈÎ ÚÈÛÙÈÎ ªË Ó Ì ٠ıÂÚ ÂÊ Ï 9671 3 Clipper Made in USA from Foreign and US Components for 3M Health Care St Paul MN 55144 1000 Charger Made in China for 3M Health Care St Paul MN 55144 1000 Blade Assembly Made in USA for 3M Health Care St Paul MN 55144 1000 ...

Page 2: ...icient power to remove course hair yet is gentle enough for fine hair It works well on all types of hair either wet or dry and in delicate areas For best performance clip hair dry The clipper has been designed and tested for use only with the 3M Surgical Clipper with Fixed Head model 9671 series battery chargers 9672 9673 9674 9675 9678 and the 3M disposable blade assembly 9670 WARNING To reduce t...

Page 3: ...pper blade assembly at a 15 to 30 degree angle to the patient s skin B For best results clip against the direction of the hair growth For problem areas stretch the skin taut while clipping To Remove Disposable Blade Assembly Assure the ON OFF switch is in the OFF position Position the clipper over an appropriate waste receptacle with the blade assembly facing downward Use your thumb to push blade ...

Page 4: ...AM to 6 00 PM Central Time After business hours a voice prompt system will take your product complaint information For customers outside of the United States please contact your local 3M Sales Representative for necessary shipping labels and packing list Please include a description of the defect with the returned unit 3M Health Care Attn Complaint Coordinator 3M Center Bldg 270 5N 01 St Paul MN 5...

Reviews: