background image

3

 

3M™ No Polish LC JG1 Connector  for 1.6-2 mm cable 

8832-JG1 UPC SM 
6832-50/OM2-JG1 MM 
6832-50/OM4-JG1 MM 

 

Instructions 

January 2016 

 

OPT01

-

IN

-

178B(E)

 

Summary of Contents for 8832-JG1 UPC SM

Page 1: ...3 3M No Polish LC JG1 Connector for 1 6 2 mm cable 8832 JG1 UPC SM 6832 50 OM2 JG1 MM 6832 50 OM4 JG1 MM Instructions January 2016 OPT01 IN 178B E...

Page 2: ...ediately flush eyes with water while holding eyelids open and continue flushing for ten minutes Contact a physician Upon skin contact wash with soap and water Refer to Safety Data Sheet for product in...

Page 3: ...sposable stripper for 250um coating removal only up to 20 stripping Note content may vary depending on product you purchased Other tools F Fiber cleaver G Fiber Stripper H Alcohol I Lint free wipe J S...

Page 4: ...inst the stop on the cable holder as shown Group aramid yarn and insert into one of the slot next to the stop 2 2 Remove cable jacket 50mm from the cable end Cable holder can be used to measure the le...

Page 5: ...e position in the clamp depending on fiber type inside cable jacket And close the cover to clamp cable Upper position cable with 900um coated fiber inside Lower position cable with 250um coated fiber...

Page 6: ...king 2nd marking 900um fiber only 2 6 Bring the sliding nest back to original position Strip buffer coating using appropriate stripping tool Stripping 250 m fiber using disposable stripper Place cable...

Page 7: ...dispose of broken off piece and repeat at Step 2 2 Note Do not touch bare glass 10mm from buffer end 2 9 Place the cable holder on a cleaver and push it to the stop Cleave the fiber per cleaver manufa...

Page 8: ...o long Right length Fiber end buffer end must be within respective gauge window 900 m buffer shown as example 2 11 Pull out buffer clamp to release buffer 2 12 Remove connector from the plastic bag At...

Page 9: ...on Do NOT TOUCH CABLE until splice is actuated at Section 2 17 2 13 Be aware of fiber guide protruding downward until splice is acutated Caution Do NOT PUSH UP fiber guide or connector may pop out fro...

Page 10: ...uation lever on the dust cap and fully press down the lever 2 18 Check if cap is fully actuated If not press down lever again 2 19 Slide boot next to the holder 2 20 Release holder cover and bring boo...

Page 11: ...holder Caution Keep holding aramid yarn and connector togeth er until boot is secured to the connector Failure to do so may induce twist in fiber resulting in fiber break later 2 23 WHILE HOLDING ARAM...

Page 12: ...2 26 Trim off excess aramid yarn with snips Termination completed 2 24 Bring boot up to connector Caution Keep holding aramid yarn and connector togeth er until boot is secured to connector Failure t...

Page 13: ...can be duplexed without using extra parts Two connectors can dovetail together to form duplex connector 3 2 Identify dovetailing features on both sides of connector body 3 3 Dovetail two connectors to...

Page 14: ...nnector re open 4 1 Insert two folks on the dust cap into slots on back side of connector 4 2 Unscrew and remove boot from connector 4 3 Pull out buffer clamp with fingers then remove fiber from the c...

Page 15: ...ion Markets Division 3M Telecommunications www 3M com Telecom 3M 2016 All rights reserved Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture f...

Reviews: