 Industrial RJ45 Modular Plug for Ethernet, Assembly Instructions

3.0  Cable Prep

3.1 

Slide case module onto cable. (Figure 2)

Figure 2

3.2 

Trim outer jacket approximately 50 mm. (Figure 3)

Figure 3

3.3 

Fold back braided shield or drain wire and remove foil shield. 

(Figure 4)

Figure 4

3.4 

Attach conductive tape over the braided shield or drain wire at the 

edge of the cable jacket. Trim off excess braid. Add spacers onto 

the cable if necessary. Be sure no braided shielding comes out of 

the end of the conductive tape. (Figure 5)

Figure 5

4.0  Termination Process

4.1 

Set cable onto the cover module so the conductive tape fits 

into the ground. (Figure 6)

Figure 6

4.2 

Attach cable clamp so the wiring diagram image matches the 

connector. (Figure 7)

Figure 7

4.3 

Remove the wiring diagram and fasten screws with a screwdriver. 

Make sure the cable is firmly secured and there are no gaps 

between the modules. (Figure 8)

Figure 8

4.4 

Place wires into the slots of the cover module following the wiring 

diagram. There is no need to untwist the wires. 

Confirm that the wires are positioned and secured at the bottom of 

the slots. (Figure 9)

Figure 9

4.5 

Place the body module onto the cover module in a parallel fashion. 

(Figure 10)

Figure 10