13
Installation and Set-Up
(Continued)
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles
box sizes up to 570 mm [22.38 in] maximum
height. If larger capacity is needed, the machine
can be adjusted to accommodate boxes up to
670 mm [26.38 in] high. Refer to page 28,
"Special Set-Up Procedures Box Height Range",
for set-up procedure.
Note Adjusting machine to accommodate
670 mm [26.38 in] high boxes also increases
minimum box size to 170 mm [6.75 in].
Note
Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems,
or other electrical requirements compatible
with local practice.
ELECTRICAL CONNECTION
The electrical control box (mounted on the lower
right side of the machine frame) contains the pre-
set circuit breaker. The box can be relocated to
the other side of the machine if desired. A
standard three conductor power cord with plug is
provided at the back of the electrical control box
for 115 Volt, 60 Hz, 2.8 Amp electrical service.
The receptacle providing this service shall be
properly grounded. Before the power cord is
INITIAL START-UP OF CASE SEALER
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for
tape loading and start-up to be sure case sealer
is properly adjusted to run boxes.
Figure 2-3 Machine Bed Height Adjustment and Lower Tape Drum Bracket Position
TAPE LEG LENGTH
Taping heads are pre-set to apply 50 mm [2 in]
long tape legs. To change tape legs to 70 mm
[2.75 in], see "Special Set-Up Procedures",
page 28.
WARNING To prevent shock and
fire hazard: Position extension cord
where it will be out of the way of foot or
vehicle traffic. Extension cord is only for
temporary use do not use for a
permanent installation.
plugged into 115 Volt, 60 Hz outlet, make sure
that all packaging materials and tools are
removed from the machine.
Do not plug
electrical cord into outlet until ready to run
machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5 mm diameter
[AWG 16], have a maximum length of 30.5 m
[100 ft], and must be properly grounded.
Summary of Contents for 3M-Matic 800asb
Page 11: ...6 THIS PAGE IS BLANK ...
Page 15: ...10 THIS PAGE IS BLANK ...
Page 19: ...14 THIS PAGE IS BLANK ...
Page 25: ...20 THIS PAGE IS BLANK ...
Page 29: ...24 THIS PAGE IS BLANK ...
Page 31: ...26 THIS PAGE IS BLANK ...
Page 34: ...29 Special Set Up Procedure Continued Figure 5 3 Upper Frame Removal ...
Page 37: ...32 THIS PAGE IS BLANK ...
Page 42: ...37 800asb Assembly 800asb Adjustable Case Sealer W AccuGlide II STD 1 1 2 Inch Taping Heads ...
Page 43: ...38 800asb Adjustable Case Sealer Figure 2799 ...
Page 45: ...40 800asb Adjustable Case Sealer Figure 4790 ...
Page 47: ...42 800asb Adjustable Case Sealer Figure 4792 ...
Page 49: ...44 800asb Adjustable Case Sealer Figure 4793 ...
Page 51: ...46 Figure 4794 800asb Adjustable Case Sealer ...
Page 53: ...48 800asb Adjustable Case Sealer Figure 4795 ...
Page 55: ...50 800asb Adjustable Case Sealer Figure 4796 ...
Page 57: ...52 800asb Adjustable Case Sealer Figure 5213 ...
Page 59: ...54 800asb Adjustable Case Sealer Figure 5213 ...
Page 61: ...56 800asb Adjustable Case Sealer Figure 6177 ...
Page 63: ...58 800asb Adjustable Case Sealer Figure 6183 1 of 2 ...
Page 65: ...60 800asb Adjustable Case Sealer Figure 6183 2 of 2 ...
Page 67: ...62 Figure 6184 1 of 2 800asb Adjustable Case Sealer ...
Page 69: ...64 Figure 6184 2 of 2 800asb Adjustable Case Sealer ...
Page 71: ...66 800asb Adjustable Case Sealer Figure 6185 1 of 2 ...
Page 73: ...68 800asb Adjustable Case Sealer Figure 6185 2 of 2 ...
Page 75: ...70 800asb Adjustable Case Sealer Figure 6186 ...
Page 77: ...72 800asb Adjustable Case Sealer Safety and Information Labels ...