3M 3M-08 Install Manual Download Page 3

Before you Connect Wires

Caution

Do not allow wires to touch each other or parts on thermostat. 
Wires must be routed through the hole in the back plate, below the 
terminal block, or they will hit parts on the cover. 

Please follow these guidelines for safe and secure wire connections.

Determine which step-by-step wiring diagram you should use. Make sure your 
wires are labeled. This may require you to find the 'other end' connection for each 
wire on your heating or airconditioning equipment and read the label there.
     If you have a wire maked "C" its connection is optional. If you do connect it the 
thermostat will draw power from the C wire and this will extend battery life. 

Optional Wire Connections 

What Wires Do you Have?

Strip insulation 3/8 in. (9.5mm) from wire ends. 
Take care not to damage the labels for each wire in handling.
Connect labeled wires only to a terminal with corresponding letter.
Bend the wire slightly, insert the wire under the contact plate and 
tighten the screw down onto the wire.  

PG

 6

PG

 5

Go To Page 13

Go To Page 14

Go To Page 12

Go To Page 11

R  -  Single source power for heat/cool
       Note: R connects to both RC and 

RH using the Orange jumper

RH or 4 - HEATING POWER

RC - COOLING POWER

W -  HEATING CONTROL

G -  FAN RELAY  

C -  Common side of Heating Power

Y -  COMPRESSOR

O - If you have this wire the 3M-08        
will not control your system.

B - If you have this wire the 3M-08 will 
     not control your system.

Summary of Contents for 3M-08

Page 1: ...at On replacement installations mount the new thermostat in place of the old one if possible On new Installations follow the guidelines listed below Locate the thermostat on an inside wall about 5 ft 1 5m above the floor and in a room that is used often Do not install it where there are unusual heating conditions such as in direct sunlight near a lamp radio television radiator register or fireplac...

Page 2: ... mount the base PG 3 PG 4 Terminal Block Switch electricity to the furnace and air conditioner OFF then proceed with the following steps Remove cover from old thermostat Most are snap on types and simply pull off Some have locking screws on the side or front These must be loosened Note the letters printed near the terminals Carefully attach labels enclosed to each wire Label the wires one at a tim...

Page 3: ...ostat will draw power from the C wire and this will extend battery life Optional Wire Connections What Wires Do you Have Strip insulation 3 8 in 9 5mm from wire ends Take care not to damage the labels for each wire in handling Connect labeled wires only to a terminal with corresponding letter Bend the wire slightly insert the wire under the contact plate and tighten the screw down onto the wire PG...

Page 4: ...thermostat will go off if the batteries die This exposes your house to unexpected heat or cold and should be avoided Follow these procedures to verify you have correctly installed the unit To check Fan If you connected the G wire fan relay Switch the FAN switch to the ON position Verify that air is blowing from the system Return to AUTO position for normal operation To check HEAT mode Set the mode...

Page 5: ...l over 1 year If the batteries are not replaced the thermostat will stop working 2 The 3M 08 can run on the C wire if available 24VAC ONLY As shown in the wiring diagrams The C wire is the other side of the 24VAC heating transformer If the C wire is used the batteries are not needed Power Options Check Unit cont Congratulations you have successfully installed your unit Please proceed to the OPERAT...

Page 6: ...o the Heater Power STEP 2 Connect the W wire to the W terminal on the thermostat This connects the heater control line to the thermostat STEP 3 Connect the G wire to the G terminal on the thermostat This connects the Fan to the thermostat Your system is now conected to the thermostat Return To Page 7 Return To Page 7 2 WIRE Heating GAS MILLIVOLT or 24vac NOTE Wires marked with the dotted line are ...

Page 7: ... Cooler compressor STEP 3 Connect the RH wire to the RH terminal on the thermostat This connects to the Heater Power STEP 4 Connect the RC wire to the RC terminal on the thermostat This connects to the Cooling Power STEP 5 Connect the W wire to the W terminal on the thermostat This connects to the heater control line STEP 6 Connect the G wire to the G terminal on the Thermostat This connects to th...

Page 8: ...ems The 3M 08 is digital You can program your desired Heat and cool temperature by setting the dial The unit uses no harmful mercury A 5 minute minimum off time in COOL protects your air conditioning system from being damaged Two AA batteries not included are used to run the thermostat in some installation C wire installations require no batteries 3M 08 Features PG 15 1006 007 Customer Support 888...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: