11
5.0 INSPECTION
5.1 INSPECTION FREQUENCY:
The Rebel SRL must be inspected at the intervals defined in “
Section 2.5 -
Inspection Frequency”
. Inspection procedures are described in the
“Inspection Checklist”
(Table 2).
5.2 UNSAFE OR DEFECTIVE CONDITIONS:
If inspection reveals an unsafe or defective condition, If
inspection reveals an unsafe condition, remove the SRL from service, mark
“UNUSABLE”,
and dispose of in
the recommended manner (see
“Section 5.4 - Disposal”
).
5.3 PRODUCT LIFE:
The functional life of Rebel SRLs is determined by work conditions and maintenance. As
long as the SRL passes inspection criteria, it may remain in service.
5.4 DISPOSAL:
Dispose of the Rebel SRL if it has been subjected to fall force or inspection reveals an unsafe or
defective condition. Before disposing of the SRL, cut the Load Indicator off of the Web Lifeline or otherwise
disable the SRL to eliminate the possibility of inadvertent reuse.
6.0 MAINTENANCE, SERVICING, AND STORAGE
6.1 CLEANING:
Cleaning procedures for the Rebel SRL are as follows:
• Periodically clean the exterior of the SRL using water and a mild soap solution. Position the SRL so
excess water can drain out. Clean labels as required.
• Clean the Web Lifeline with water and mild soap solution. Rinse and thoroughly air dry. Do not force dry
with heat. The lifeline should be dry before allowing it to retract into the housing. An excessive buildup
of dirt, paint, etc. may prevent the lifeline from fully retracting back into the housing causing a potential
free fall hazard.
IMPORTANT:
If the lifeline contacts acids or other caustic chemicals, remove the SRL from service
and wash with water and a mild soap solution. Inspect the SRL per Table 2 before returning to
service.
6.2 SERVICE:
Rebel SRLs are not repairable. If the SRL has been subjected to fall force or inspection reveals
an unsafe or defective condition, remove the SRL from service, mark
“UNUSABLE”,
and dispose of in the
recommended manner (see
“Section 5.4 - Disposal”
).
6.3 STORAGE:
Store Rebel SRLs in a cool, dry, clean environment out of direct sunlight. Avoid areas where
chemical vapors may exist. Thoroughly inspect the SRL after any period of extended storage.
7.0 SPECIFICATIONS
7.1 PERFORMANCE:
Your Rebel SRL has been tested and certified to the performance requirements of
the standard(s) identified on the cover of this instruction manual. See
“Section 2.0 - Limitations &
Requirements”
for performance specifications.
7.2 MATERIALS:
Material specifications for the Rebel SRL are as follows:
Housing:
Nylon, UV Resistant
Motor Spring:
Stainless Steel
Drum:
Nylon, Type 6/6
Swivel:
Zinc Plated Steel
Fasteners:
Zinc Plated Steel Screws; Stainless
Steel Rivets
Lifeline:
Polyester Web
Locking Pawls:
Stainless Steel
Load Indicator
Cover: PVC Tubing
Web: Polyester
Main Shaft:
Stainless Steel
End
Connectors:
(See Figure 1)
Gate Opening
Gate Strength
Steel Carabiner
3/4 in (19 mm)
3,600 lb (16 kN)
Steel Snap Hook
3/4 in (19 mm)
3,600 lb (16 kN)
Steel Swiveling Snap Hook
3/4 in (19 mm)
3,600 lb (16 kN)
Steel Rebar Hook
2 1/4 in (57 mm)
3,600 lb (16 kN)
7.3 LABELING:
Figure 14 illustrates Rebel SRL labeling. All labels on the SRL must be present and fully legible.
Summary of Contents for 3100400
Page 13: ...13 Figure 14 Labeling ...