background image

3

Instructions

For the Assembly of the 68, 80, 100 Position MDR
103XX-12R1-00 and 103XX-12S1-00 Metal Junction
Shells for Pleated Foil Cable and 101XX-6000 Series
MDR Plug.

General:

The 103XX-12R1-00 MDR Junction Shells provide
grounding, EMI/RFI shielding, thumb screw retention, and
strain relief .

Kit Contents:

4 each

M2.5 flat head thread 
cutting screws

2 each

Metal shell halves

2 each

Thumb screws

2 each

Elastomer gaskets

2 each

Metal strain reliefs

NOTE: Kit 103XX-12S1 does
not include the elastomer
gasket material. Contact 3M for details.

Tools Needed:

• 3430-7000 Hand Tool (Scribe)
• Straight edge (Metal ruler)
• Philips screwdriver (No. 1 point head) 
• 4000-2000 Cable Splitter 
• 3640 or 3335 Assembly Press  

NOTE: Because of the torque/pressure involved with
using the thread cutting screws, make sure the
recommended No. 1 pt. Philips screwdriver is used.

Cable Preparation

The cable, shield, and jacket should be trimmed to the
recommended dimensions shown in Figure 2.

• 3/4" cable should be exposed.
• 1/4" pleated foil should be exposed.
• 1/2" cable jacket should be trimmed along the side. 

After terminating the connector to the cable, the assembly is
ready to be installed in the junction shell. 

Assembly

1. Place the top half of the junction shell next to the bottom

half, with the inside of each half facing up. See Figure 3.

• The top half of the shell has four holes on the side with

the 3M logo.

• The bottom half of the shell has no holes on the side with

the 3M logo. See Figure 4.

2. Insert the Elastomer Gasket in both halves as shown in

Figure 5. (Gasket material in vertical position.)

3. Insert the metal strain reliefs, with flat side facing up as

shown in Figure 5.

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

1-1/2"

1/4"

Bottom Half

Top Half

3/4"

1/2"

Reviews: