Problem 

Cause 

Solution 

The indicator  LEDs  of transmit-
tor and receiver do not light 

12  Vdc.  not  present  or  defective  
power source present. 

The    ALARM  LED  does  not 
light and the alarm trigger relay 
does not change state if both  
beams are interupted.   

1- Check if the receiver is getting the 
barrier  signal  from  another  near  by 
transmitter. 
2-  Check  if  both  beams  are  interup-
ted at the same time. 
3-  Check  if  the  trigger  response  time 
is correctly set. 

1-  Remove  the  transmitter    that  is 
causing the interference. 
2- Make sure that both beams are 
 interupted 
3- Regulate the trigger reponse 
time  so  that  the  unit  will  function 
correctly. 

The  ALARM  LED  lights  when 
both  IR  beams  are  interuped 
but  the  contol  panel  does  not 
receive the trigger alarm signal.  

1-  Check  the  terminal  connections 
and if there is an open or short 
circuit. 
2-  Check  for  error  on  the  terminal 
connections. 

1- Check for damaged cables 
 
2- Check that the terminal 
connection are correct. 

ALARM  trigger  LED  is  alway 
light. 

1- The IR beams are not aligned. 
2-  There  is  something  that  prevents 
the IR beam from arriving. 
3- The sensor cover is very dirty. 

1- Re-align the IR beams and test.  
2- Remove any obstacales that 
can prevent the IR beams to arrive 
3- Clean the sensor cover. 

False alarm signal 

1- Bad cable connections to the 
 control panel. 
2- Bad 12 Vdc. Power source. 
3-  Obtacales present that  will interup 
the  IR  beams  always  or  only  when 
there is wind 
4- Instable coloum 
5-  The  signal  received  is  not  strong 
enough. Below 2.3 V. 
6-  The  trigger  response  time  is  not 
correct. 

1-  Check  that  the  cables  make 
good connection. 
2-  Check  that  the  input  power  is 
okay. 
3-  Remove all obstacales or   
change the IR beam path. 
4-  Change or fix better the support 
5-  Re-align the the IR beams 
6-  Change  the  trigger  response 
time so that the unit works 
correctly. 

Check  the  connection  cables  for 
short circuit or bad connection. 

7 - In case of problems

 

8 - Techical Characteristics

 

MAXIMUM RANGE . . . . . . . . . . . . . . . . 

 

NUMBER OF BEAMS . . . . . . . . . . . . . . 

OPERATING MODE . . . . . . . . . . . . . . . .

 

TECHNOLOGY IR TRANSMISSION . . .   

RISPONSE TIME . . . . . . . . . . . . . . . . . . 

ALARM OUTPUT . . . . . . . . . . . . . . . . .    

POWER . . . . . . . . . . . . . . . . . . . . .  . . . .  

CURRENT DRAIN . . . . . . . . . . . . . . . . .   

FUNCTIONING TEMPERATURE. . . . . . 

HORIZONTAL ANGLE. . . .  . . . . . . . . . .  

VERTICAL ANGLE . . . . . . .  . . . . . . . . .  

SENSOR MATERIAL. . .  . . . . . . . . . . . .  

WEIGHT. . . . . . . . .  . . . . . . . . . . . . . . . .  

Indoor 300 mt. Outdoor 100 mT.

 

3

 

Interuption of both beams together

 

Active Infrared 

From 50 to 700 Msec 

30 V. 0,5 mA max. (a.c. or d.c.) 

From 10,5  to 18 Vd.c. 

80 mA max. 

Da –25°C to +55°C (from 5% to 95% humidity) 

180° (-90°+ 90°) 

20° (-10°+ 10°) 

ABS 

Trasmitter 630 g - Riceiver 660 g 

Summary of Contents for BSE-150

Page 1: ... OUTDOOR ACTIVE INDOOR AND OUTDOOR ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH INFRARED BARRIER WITH INFRARED BARRIER WITH 3 BEAMS OF PROTECTION 3 BEAMS OF PROTECTION 3 BEAMS OF PROTECTION INSTALLATION INSTALLATION INSTALLATION MANUAL MANUAL MANUAL BSE 150 ...

Page 2: ...e regulation Horizontal axial screw regulation 2 Connections and Indications The receiver has 3 LEDs that indicate the inten sity of the infrared signal received and the alarm trigger LEVEL red led The more intense the luminosità the more intense the signal received from transmitter GOOD green led this will light if there is a good level of transmission at least 2 3V on the tester ALARM red led Th...

Page 3: ...objects intrupt the line of sight of the barriers 3 Installation precautions Avoid that a receiver can by error receive the signal transmitted form the the wrong unit See below Trasmitter Receiver Receiver Trasmitter ERROR Trasmitter Receiver Trasmitter Receiver CORRECT Connection terminals 1 Not used 2 Power input 12Vd c 3 Negative power input 4 Common relay 5 Normally open Dry contact relay outp...

Page 4: ...rol panel 3 1 4 Fix to the wall the metal base of the sensor Installation on column 3 2 1 Drill hole for the cable on the top of the column Cable Hole See fig page 2 for terminal conn 3 2 4 See below how to fix 2 units to the same column 3 1 5 Connect the cable to the desire terminal blocks 3 2 3 Fix the metal base to the Column as shown below 3 Installation procedure Wall mounting 3 2 2 Rimove th...

Page 5: ...e points based on the polarity in the holes marked and 2 Regulate the vertical and horizontal angles until the voltage is at a maximum Visual test 1 Remove the front cover and power up both receiver and tran smitter 2 Align the beams between the transmitter and receiver 3 On the riceiver by using the vertical and horizontal alignment tools you may better align the receiver and the transmitter See ...

Page 6: ...r responce 1 Run 6 9m sec 2 Fast Walk 1 2m s 3 Normal walk 0 7m s 4 Slow Movement 0 3 0 5m s 5 Slow Walk 0 1 0 3m s With the below figures you may regulate the trigger response time as desired 1 5 2 4 RESPONSE TIME 3 Verify the effects on the barrier based on the selected walk If you are not satisfied with the results change this regulation until you obtain the best possible results ...

Page 7: ...rom arriving 3 The sensor cover is very dirty 1 Re align the IR beams and test 2 Remove any obstacales that can prevent the IR beams to arrive 3 Clean the sensor cover False alarm signal 1 Bad cable connections to the control panel 2 Bad 12 Vdc Power source 3 Obtacales present that will interup the IR beams always or only when there is wind 4 Instable coloum 5 The signal received is not strong eno...

Page 8: ...make improvments to this product without previous notice Last revision 07 02 2013 ENGLISH TRE i SYSTEMS S r l TRE i SYSTEMS S r l TRE i SYSTEMS S r l TRE i SYSTEMS S r l Via del Melograno N 13 00040 Ariccia Roma Italy Tel 39 06 97249118 Fax 39 06 45557618 Tre i Systems e mail m tomasino treisystems com Website www treisystems com Dispose of all waste material in appropriate garbage disposal contai...

Reviews: