Installation
Drill Ø10mm hole, minimum 65mm
deep.
Remove drilling debris with a blowout
bulb or with compressed air.
With screw in anchor (3-15-311A), use a
hammer to insert anchor.
1
Install Ceiling Anchor for the First Cable Assembly
*If anchoring in concrete follow Steps 1a-f, if anchoring in drywall follow Steps 1g-l. if anchoring in wood follow Steps 1m-n.
b
c
a
Concrete Installation
e
f
d
Place a washer under the screw head.
Torque the screw to 15 Nm.
Remove screw.