XY axes CALIBRATION OF 3DGENCE DOUBLE 

 

   

 

05.2018 

3DGence DOUBLE | Support: +48 438 98 64 | www.3dgence.com/support 

 

8.

 

If the printing does not comply with these requirements, make following corrections: 
a) 

choose from printer’s menu following commands:

 

MENU 

 ADVANCED 

 XY CALIB. 

b) enter the original dimension to X-axis = 100, 
c) enter the measured dimension on X-axis, 
d) enter the original dimension to X-axis = 100, 
e) enter the measured dimension on Y-axis, 
f) save the measurements by choosing: 

SAVE

 
9.

 

Print the model again, then repeat the actions until the measurements oscillate between 99,95 

 100,05 

(the tolerance 

±

 0,05) and the difference between the measurements will be around 0 

 0,05. 

 