Service manual:
XY AXES CALIBRATION
3DGence DOUBLE
Page 1: ...Service manual XY AXES CALIBRATION 3DGence DOUBLE ...
Page 2: ...l the colour lights turn green then remove the model from the heatbed and wait about 5 minutes to stabilize the temperature 6 Put the cross on a flat surface and check the measurements on X axis and Y axis a Place a caliper on the upper part of the cross lean the ends of the clamps on as surface put the limb of the cross into outside large jaws b Check and note down the measure on X axis and Y axi...
Page 3: ...commands MENU ADVANCED XY CALIB b enter the original dimension to X axis 100 c enter the measured dimension on X axis d enter the original dimension to X axis 100 e enter the measured dimension on Y axis f save the measurements by choosing SAVE 9 Print the model again then repeat the actions until the measurements oscillate between 99 95 100 05 the tolerance 0 05 and the difference between the mea...