5.3 Removing 3D Prints
Before removing 3D prints, make sure that the machine is turned off.
Beware that water may drip from the lid when it is opened. To minimize the risk of getting wet, allow for the water to run off the
window before opening.
WARNING: DO NOT, AT ANY TIME, WHEN THE LID IS OPEN TURN ON THE WATER AS THE HIGH-PRESSURE WATER
JET CAN CAUSE SERIOUS INJURY.
5.4 Changing the Filter
Please allow for the water to flow through the filter before removing the filter. If not, there will be water on the floor. You can
visually check if there is still water in the filter before removing it.
1. Open the grid in the blasting chamber by lifting the handle.
2. Unscrew the filter holder.
3. Remove the filter by lifting it straight up and throwing it in the trash.
4. Place a new filter in the filter spot.
5. Screw the filter holder in place and make sure it presses firmly against the filter. If not, dirty water will get into the machine's
internal water systems and damage the machine.
Figure 5: The filter is located below the grid in the blasting chamber.
3D Systems, Inc.
9
p/n 74-D002, Rev. A