80
Platform Installation
The RDM must be in the machine before this process starts. When correctly installed, the platform
sits on the elevator platform mount.
5. Go to the Control Panel, select a part,
and start a build.
6. When correctly installed and started, the
elevator main stage moves to the Build Start
position.
is an
alternate method to move the platform
to the build start position. With this,
the user can also remove bubbles prior
to starting a new build.
1. Make sure that the elevator motion stage is at its offload
position.
2. Place the platform on two
L-shaped guides
in the rear
of the RDM.
3. Push the platform against the
front platform guides
.
4. Make sure that the
notches
in the platform engage into the
front platform guides.
70696 Revision 1C 27-Aug-08