3D Systems ProJet MJP 5600 Original Instructions Manual Download Page 6

A freezer is required for cooling parts after builds. The size of the freezer must be able to accommodate

the build platform’s size of (L x W) 55 x 41.3 cm,  (22  x 16.25 in.) 
 
Access Area Surrounding The Printer 
At least 36” (908mm) of unobstructed floor space is recommended around each side of the printer to

allow unobstructed service access to the drawers and doors. 
The 36 inch distance of unobstructed access around the printer is required for service.  The

power cord is classified as the emergency disconnect device for this printer.  In an emergency

situation, the service technician must have unobstructed access to the power cord.

 

 

Unit Portability

CAUTION: NEVER unpack, assemble, or connect any component of the shipment without

the aid of a qualified, 3D Systems Field Service Engineer or 3D Systems certified

servicing reseller. 3D Systems accepts no responsibility for damaged, defective, or

incomplete systems uncrated by anyone other than 3D Systems Field Service Engineer

or authorized reseller.

CAUTION: The casters provided have a small diameter and are not intended for use on rough or uneven surfaces including
carpet.  
CAUTION: To avoid the risk of tipping the printer when moving between locations, only push from the left or right end  of the
printer.  Do not push from the front or back of the printer.

 
The printer is intended to be lifted from the crate base using a fork lift and placed on the casters to roll

to its final destination.  The ProJet Printing System is equipped with caster-type rollers. Leveling can be

accomplished  using the threaded leveling feet. 

 

CAUTION: Once the printer is installed, it cannot be moved without the aid of a qualified, 3D Systems Field Service

Engineer or 3D Systems certified servicing reseller. 3D Systems accepts no responsibility for damage to the printer by

anyone other than 3D Systems Field Service Engineer or authorized reseller. 

Summary of Contents for ProJet MJP 5600

Page 1: ...m projetmjp5600 facility requirements guide for the most up to date Facility Requirements Guide About this manual This document includes all of the overall facility requirements that will be needed to have a successful installation when our 3D Systems Field Service Engineer or 3D Systems certified servicing reseller arrive to install your 3D printer ...

Page 2: ...A description of hardware software part material networking components and documentation that comprise the ProJet Professional Printing System An overview of the site requirements in typical engineering and design work spaces These involve basic access electrical and environmental conditions for configuring a safe and efficient work area A checklist is included to ensure that the facility is adequate...

Page 3: ...n or behind the access panel Avoid contact Hot surfaces can cause burn injury or fire Allow surface to cool before touching Access panels are for service only and should be opened only by certified service personnel or trained maintenance personnel HARMFUL IRRITANT WARNING Indicates that skin or eye irritation could result while exposed to a chemical composition CAUTION Indicates the possibility of ...

Page 4: ...terials VisiJet build material is for production of the actual prints and the VisiJet support material produces the required support structures necessary to build 3 dimensional prints These materials are formulated exclusively for use with the ProJet Professional Printing System What is Included with a ProJet Professional Printing System The printer ships with one crated ProJet Professional Printi...

Page 5: ...Dimensions Printer Weight and Dimensions Weight 935 kg 2060 lbs Dimensions H x W x D 162 x 170 x 90 cm 63 8 x 66 9 x 35 4 in Printer Weight and Dimensions Crated Weight 1180 Kg 2600 lbs Dimensions H x W x D 203 2 x 200 7 x 165 cm 80 x 79 x 65 in Space Planning Below is a suggested floor plan for the printer installation Each printer requires use of a dedicated circuit Multiple printers CAN NOT be l...

Page 6: ... accepts no responsibility for damaged defective or incomplete systems uncrated by anyone other than 3D Systems Field Service Engineer or authorized reseller CAUTION The casters provided have a small diameter and are not intended for use on rough or uneven surfaces including carpet CAUTION To avoid the risk of tipping the printer when moving between locations only push from the left or right end o...

Page 7: ...may be affected by an outside source e g lightning strikes power interruption etc A 5kVA UPS supplying 120V to the product is required The machine shall be powered by 100 120V nominal when a UPS is utilized Some examples of suppliers are Toshiba APC Eaton and Liebert For International 230V markets a stepdown transformer is always required Power loss during a build will cause the build to fail and c...

Page 8: ...eller at the time of installation and should also be known by personnel installing the client software They will need access either to the appropriate subnet mask or the individual IP address of each printer to complete the workstation software installation and to enable access to any printer on the network Not all networks have TCP IP installed Make sure to have a network administrator check that...

Page 9: ...t with local and other applicable laws and regulations governing such materials Refer to the VisiJet materials SDS sheets prior to shipment of the ProJet Professional Modeling System Discuss your organization s methods for disposing or recycling of such material with your facilities manager or for more information contact 3D Systems Customer Support Hot line here ...

Page 10: ...imits The operating temperature range should be between 18 28 C 64 82 F optimal operational environment is 21 24 C 70 75 F Humidity Humidity should be maintained at a minimum 30 and a maximum 70 relative humidity Optimal is 35 45 relative humidity Lighting The printer is equipped with its own internal light build chamber and back lit operating panel control with display Vibration and Shock The pri...

Page 11: ...ower the printer ____ Optional UPS customer purchased 5kVA minimum properly wired for input and output voltages to operate the machine at designated voltages ____ Storage for extra printer material containers and other consumables ____ At least one 1 networked graphics workstation or CAD CAM CAE terminal meeting the requirements described in Client Workstation Requirements Note Retain the shipping...

Page 12: ...rom the shipper s truck has been arranged forklift is required and is available to transfer the crate s to the de crating location NETWORK CONNECTION IS INSTALLED An RJ45 UTP female connection jack Ethernet network connection for EACH printer that is to be installed at the delivery site must be installed tested and functioning Operating system and workstation configurations are compatible and meet ...

Page 13: ... with 3D Systems Customer Service Representative If alteration are made without consulting 3D Systems it may void the system s warranty Customer Signature _________________________________________________________ Date _______________ ...

Page 14: ...ct damages arising from the use of this document however caused and on any theory of liability This limitation will apply even if 3D Systems or an authorized dealer or representative has been otherwise advised of the possibility of such damage This document in whole or in part may be changed or modified at any time at the sole discretion of 3D Systems without notice ...

Page 15: ...rom your 3 D digital data We are dedicated to developing a relationship that extends beyond the terms of the sale Please take the time to contact 3D Systems with questions comments or suggestions about your ProJet Professional Printing System or other products or services 3D Systems strives for higher quality better products and comprehensive services to benefit our customers ...

Page 16: ...problem occurred for example when you submitted a job during the beginning or the end of a print or after power off recovery etc Customer Support Hotline Please contact your Customer Support Hotline at one of the following numbers US and Canada 888 598 1438 UK and EMEA 44 1442 279883 International 1 803 326 3930 General ProJet MJP 5600 service procedures must be performed only by a 3D Systems certi...

Page 17: ......