Technical Reference
59
&Un
When set above 0, the value chosen from the table sets the floor connect speed (the lowest
acceptable connect speed). If a connection cannot be made at or above this speed, the modem will
hang up. This command can also be used in conjunction with &Nn.
Note: &U17 through &U39 apply only to V.90 products.
&N=0
&N>0
&U=0
Connects at best
Attempts a connection at the speed
possible speed
defined by &N
n
.
between your modem
and the remote modem.
Note: These factory default
settings should be sufficient
for most users.
&U>0
Connects at any speed
Connects at any
faster than the value
speed between
&U
n.
&N
n
. and &U
n.