background image

 

Inserting or Removing the Module

 

CAUTION:

 

 Modules are made of extremely sensitive electronic 

 

components that may be damaged by static electricity. Handle 

 

modules only by the front panel and by their non–conducting 

 

edges, and wear a wrist strap attached to an unpainted part of 

 

the probe’s chassis.

 

Inserting the Module

 

WARNING:

 

  Do not remove the blanking plate with the power 

 

still connected.

 

1

 

Remove the blanking plate from the module slot:

 

a

 

Turn the two captive screws a quarter turn anti-clockwise.

 

b

 

Pull the blanking plate towards you.

 

2

 

Insert the FDDI DAS Module:

 

a

 

Align the rear edges of the module with the rails on each 

 

side of the module slot. Slide the module into the slot until 

 

the face of the module is flush with the front panel of the 

 

probe. Press firmly to ensure connection.

 

b

 

Secure the two captive screws by turning them a quarter 

 

turn clockwise.

 

Removing the Module

 

WARNING:

 

  Do not remove the module with the power still 

 

connected.

 

1

 

Remove the FDDI DAS Module from the module slot:

 

a

 

Turn the two captive screws a quarter turn anti-clockwise.

 

b

 

Pull the module towards you.

 

2

 

Insert another module or a blanking plate.

 

Network Connection

 

Cables and Connectors

 

SC–to–SC or SC–to–MIC cable, multimode 62.5/125

µ

 

m or 

 

50/125

µ

 

m, with multimode duplex SC–type connector.

 

Optical Bypass Switch Connector

 

6–pin Mini–DIN connector with the following pin assignments:

 

Connecting to a Network

 

1

 

Install an FDDI DAS Module in the Enterprise Monitor 

 

See 

 

 

Inserting or Removing the Module

 

 

.

 

2

 

Disconnect the cable between two neighboring devices.

 

3

 

Insert a cable from the A port of the FDDI DAS Module to 

 

the B port of one of the neighboring devices.

 

4

 

Insert a cable from the B port of the FDDI DAS Module to 

 

the A port of the other neighboring device.

 

Connecting to an 

 

Optical Bypass Switch (OBS)

 

1

 

Plug the A and B connectors from a network device into 

 

the B and A receptacles respectively on the OBS.

 

2

 

Plug the A and B SC–type connectors of the OBS into the 

 

A and B receptacles respectively on the Enterprise 

 

Monitor.

 

3

 

Plug the OBS 6–pin mini–DIN power connector into the 

 

Optical Bypass socket on the Enterprise Monitor.

 

Pin #

 

Assignment

 

Pin #

 

Assignment

 

1

 

+5V Secondary Switch

 

4

 

GND Secondary Switch

 

2

 

+5V Primary Switch

 

5

 

GND

 

3

 

GND Primary Switch

 

6

 

Switch Present