R

 

FDDI Module 
Installation Guide

 

For the CoreBuilder

 

 

 

 

3500 System

Module Description

 

Your system connects to FDDI networks using one of these modules: 

 

 

FDDI MMF

 

 

 

(Part Number: 3C35410) 

 

 

 

 

Connects to multimode 

fiber-optic cable, providing a transmission distance of up to 2 km 
(1.2 mi) using 62.5 micron fiber. 

 

 

FDDI SMF (Part Number: 3C35420) 

 

— 

 

Connects to single-mode 

fiber-optic cable, providing a transmission distance of approximately 
14.4 km (8.9 mi) using 9 micron fiber. 

Each FDDI module contains six FDDI ports that use fiber (SC) connectors. 
Each port provides a 100 Mbps FDDI connection over fiber-optic cable. 
The ports support both SAS (single-attached station) and DAS 
(dual-attached station) modes, for a maximum of six SAS connections or 
three DAS connections. You can remove and replace the modules with 
the system on.

 

CAUTION: 

 

The FDDI module requires release 2.0.0 or higher of the 

CoreBuilder 3500 system software. Download this software from the 
following 3Com Web site:

 

http://support.3Com.com/index.htm

 

Figure 1 shows the FDDI MMF module. The FDDI SMF module is similar

 

Figure 1   

 

FDDI MMF Module

FDDI MMF
3C35410

PWR

INS

ERR

L
E
T

L
E
T

L
E
T

L
E
T

L
E
T

L
E
T

A1

A2

A3

B4

B5

B6

Summary of Contents for FDDI MMF

Page 1: ...s six FDDI ports that use fiber SC connectors Each port provides a 100 Mbps FDDI connection over fiber optic cable The ports support both SAS single attached station and DAS dual attached station modes for a maximum of six SAS connections or three DAS connections You can remove and replace the modules with the system on CAUTION The FDDI module requires release 2 0 0 or higher of the CoreBuilder 35...

Page 2: ...A1 B4 2 A2 B5 3 A3 B6 Status LED Name Color Description Module Status PWR Power Green The module is receiving power INS Board Inserted Yellow The module is partially inserted ERR Board Error Yellow The module did not successfully complete the power up diagnostics Blinking Yellow A hardware software incompatibility has occurred Port Status L Link Green A valid link has been established and the port...

Page 3: ...inside the chassis with your hands or fingers ESD Safety Information Electrostatic discharge ESD can damage components on the module ESD which occurs when the module is improperly handled can cause complete or intermittent failures To prevent ESD related damage Always wear an ESD wrist strap connected to proper ground Ensure that the wrist strap makes good skin contact Keep the module in its antis...

Page 4: ...higher of the CoreBuilder 3500 system software Read before installing in an empty slot Your system is shipped with no modules installed and with protective faceplates covering the installation slots Before you install the module remove the protective faceplate that covers the selected installation slot To remove a faceplate 1 Loosen the two captive screws that secure the faceplate to the chassis 2...

Page 5: ...tatic bag 1 Put on the ESD wrist strap and ensure that you are properly grounded 2 Remove the module from its antistatic bag WARNING If the system is on when you are installing the module do not insert any metal objects into the open slot for example a screwdriver or a finger with jewelry Doing so can cause burns or other bodily harm as well as system damage 3 With the injector ejector handles in ...

Page 6: ...information about defining IP interfaces see your system s Implementation Guide These documents are on the Software and Documentation CD Module Diagnostics The system runs diagnostics tests at power up or when you replace a module with the power on During diagnostics tests the module s Error LED lights yellow When the diagnostics tests are successfully completed the Error LED turns off and the por...

Page 7: ...Customer on and after January 1 1998 that are date sensitive will continue performing properly with regard to such date data on and after January 1 2000 provided that all other products used by Customer in connection or combination with the 3Com products including hardware software and firmware accurately exchange date data with the 3Com products with the exception of those products identified at ...

Page 8: ...SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT 3COM S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or ...

Reviews: