background image

The SuperStack

®

 3 Baseline 10/100 Switch 48-Port 

10BASE-T/100BASE-TX plus 2-Port Gigabit is a versatile, easy-to-use 
unmanaged switch. It is ideal for users who want the high-speed per-
formance of 10/100 switching with the added functionality of two 
Gigabit links, but do not need sophisticated management capabilities. 
This Baseline Switch is shipped ready for use; no configuration is nec-
essary.

The Baseline Switch has 48 shielded RJ-45, 10/100 Mbps 
auto-negotiating ports and two shielded RJ-45, 10/100/1000BASE-T 
ports on the front panel. Each port automatically determines the 
speed and duplex mode of the connected equipment and provides a 
suitable switched connection. Each port also supports automatic 
MDI/MDI-X detection.

The Baseline Switch is suited for office use where it can be free 
standing, or rack mounted (in a wiring closet or equipment room).

The Baseline Switch comes with:

„

One power cord

„

Four self-adhesive rubber pads

„

One mounting kit

The Baseline Switch provides high performance switched connections 
to 10 Mbps and 100 Mbps hubs, servers and workstations that need 
a dedicated switched link and two 10/100/1000 BASE-T ports that 
can connect to other 10/100/1000 BASE-T ports or servers and 
workstations.
This diagram shows a typical configuration:

I

NTRODUCTION

100Mbps or 1000 Mbps link

10 Mbps link

1000 Mbps connections

to backbone or

server/workstation

Endstations and servers

on switched 10 Mbps and

100 Mbps connections

Endstations on shared

10 Mbps connections

Baseline Switch

Local server

Endstations on shared

100 Mbps connections

Baseline Dual Speed Hub

Baseline Hub

SuperStack

®

 3 Baseline 10/100 Switch 48-Port 10BASE-T/100BASE-TX 

plus 2-Port Gigabit (3C16476) User Guide

DUA1647-6AAA01

1

Summary of Contents for Baseline 3C16476

Page 1: ... for office use where it can be free standing or rack mounted in a wiring closet or equipment room The Baseline Switch comes with One power cord Four self adhesive rubber pads One mounting kit The Baseline Switch provides high performance switched connections to 10 Mbps and 100 Mbps hubs servers and workstations that need a dedicated switched link and two 10 100 1000 BASE T ports that can connect ...

Page 2: ... Ethernet devices Full duplex allows packets to be transmitted and received simultaneously which in effect doubles the potential throughput of a link These ports require either straight through or cross over Category 5 cables with RJ 45 connectors at both ends The maximum UTP cable length is 100 m 328 ft over Category 5 cable The 10 100 1000BASE T ports will auto negotiate to the appropriate speed...

Page 3: ...he side of the case is not restricted 3Com recommends that you provide a min imum of 25 mm 1 in clearance The air is as free from dust as possible Temperature operating limits are not likely to be exceeded It is recommended that the unit is installed in a clean air conditioned environment It is always good practice to wear an anti static wrist strap when installing network equipment connected to a...

Page 4: ... Reconnect all cables Refer to the information about LEDs given earlier in this guide to see if the problem can be identified and rectified Here are some common problems that can occur Link Status LED not lit for a port that has a connection There is a problem with this connection Check that The device being connected to is powered on and operating cor rectly The cable is connected at both ends Th...

Page 5: ...oit être facile Vous ne pouvez mettre l appareil hors circuit qu en débranchant son cordon électrique au niveau de cette prise L appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme CEI 60950 Ces conditions ne sont maintenues que si l équipement auquel il est raccordé fonctionne dans les mêmes conditions France et Pérou uniquement Ce groupe ne peut pas être a...

Page 6: ...uipment in a residential area is likely to cause harmful interference to radio communications in which case the user will be required to correct the interference at their own expense Information To The User If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference ...

Page 7: ...roblem before calling Please note that these numbers are correct at the time of publication Refer to the 3Com Web site for updated information PRODUCTS TECHNICAL SUPPORT Country Telephone Number Country Telephone Number Country Telephone Number Asia Pacific Rim Australia Hong Kong India Indonesia 1 800 678 515 800 933 486 61 2 9424 5179 or 000800 650 1111 001 803 61009 Japan Malaysia New Zealand P...

Page 8: ... a copy please contact 3Com and a copy will be provided to you UNITED STATES GOVERNMENT LEGEND If you are a United States government agency then this documentation and the software described herein are provided to you subject to the following All technical data and computer software are commercial in nature and developed solely at private expense Software is delivered as Commercial Computer Softwa...

Reviews: