Please read the following safety information carefully 
before installing the Switch.

WARNING:

 Installation and removal of the unit must be carried out by 

qualified personnel only.

„

If installing Switch 2824/Switch 2816 in a stack with other 3Com Hub or 
Switch units, larger units must be installed below the narrower Hub or 
Switch units.

„

The unit must be connected to an earthed (grounded) outlet to comply with 
international safety standards.

„

Do not connect the unit to an A.C. outlet (power supply) without an earth 
(ground) connection.

„

The appliance coupler (the connector to the unit and not the wall plug) 
must have a configuration for mating with an EN 60320/IEC 320 appliance 
inlet.

„

The socket outlet must be near to the unit and easily accessible. You can 
only remove power from the unit by disconnecting the power cord from the 
outlet.

„

This unit operates under SELV (Safety Extra Low Voltage) conditions 
according to IEC 60950. The conditions are only maintained if the 
equipment to which it is connected also operates under SELV conditions.

France and Peru only

This unit cannot be powered from IT

 supplies. If your supplies are of IT type, this 

unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with 

the secondary connection point labelled Neutral, connected directly to earth 
(ground).

 Impédance à la terre

Power Cord Set

This must be approved for the country where it will be used. e.g.

Veuillez lire à fond l'information de la sécurité suivante 
avant d'installer le Switch.

AVERTISSEMENT: 

L’installation et la dépose de ce groupe doivent être 

confiés à un personnel qualifié.

„

Si vous entassez l’unité Switch avec les unités SuperStack II Hub, l’unité 
Switch doit être installée en dessous des unités Hub plus étroites.

„

Ne branchez pas votre appareil sur une prise secteur (alimentation 
électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la 
masse).

„

Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la 
masse) afin de respecter les normes internationales de sécurité.

„

Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) 
doit respecter une configuration qui permet un branchement sur une entrée 
d’appareil EN 60320/IEC 320.

„

La prise secteur doit se trouver à proximité de l’appareil et son accès doit 
être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant 
son cordon électrique au niveau de cette prise.

„

L’appareil fonctionne à une tension extrêmement basse de sécurité qui est 
conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si 
l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.

France et Pérou uniquement:

Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos 
alimentations sont du type impédance à la terre, ce groupe doit être alimenté par 
une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 
1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec 
raccordement direct à la terre (masse).

Cordon électrique

Il doit être agréé dans le pays d’utilisation.

Bitte unbedingt vor dem Einbauen des Switches die 
folgenden Sicherheitsanweisungen durchlesen.

WARNUNG:

 Die Installation und der Ausbau des Geräts darf nur durch 

Fachpersonal erfolgen.

„

Wenn der Switch 2824/Switch 2816 mit anderen 3Com Hubs oder Switche 
gestapelt werden soll, müssen grössere Geräte unter den schmaleren Hubs 
eingebaut werden.

„

Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose 
angeschlossen werden.

„

Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche 
die internationalen Sicherheitsnormen erfüllt.

„

Der Gerätestecker (der Anschluß an das Gerät, nicht der 
Wandsteckdosenstecker) muß einen gemäß EN 60320/IEC 320 
konfigurierten Geräteeingang haben.

„

Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. 
Die Stromversorgung des Geräts kann nur durch Herausziehen des 
Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.

„

Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen 
(Sicherheitskleinstspannung) gemäß IEC 60950. Diese Bedingungen sind nur 
gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter 
SELV-Bedingungen betrieben werden.

S

AFETY

 I

NFORMATION

U.S.A. and 
Canada

The cord set must be UL-approved and CSA certified.

The minimum specifications for the flexible cord are:
No. 18 AWG
Type SV or SJ
3-conductor

The cord set must have a rated current capacity of at least 
10 A.

The attachment plug must be an earth-grounding type with a 
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) 
configuration.

Denmark

The supply plug must comply with Section 107-2-D1, Standard 
DK2-1a or DK2-5a.

Switzerland

The supply plug must comply with SEV/ASE 1011.

UK

The supply plug must comply with BS1363 (3-pin 13-amp) and 
be fitted with a 5 A fuse which complies with BS1362.

The mains cord must be <HAR> or <BASEC> marked and be 
of type HO3VVF3GO.75 (minimum).

Europe

The supply plug must comply with CEE7/7 (“SCHUKO”)

The mains cord must be <HAR> or <BASEC> marked and be 
of type HO3VVF3GO.75 (minimum).

L’

INFORMATION

 

DE

 S

É

CURIT

É

 I

MPORTANTE

Etats-Unis et 
Canada:

Le cordon doit avoir reçu l’homologation des UL et un 
certificat de la CSA.

Le cordon souple doit respecter, à titre minimum, les 
spécifications suivantes:
calibre 18 AWG
type SV ou SJ
à 3 conducteurs

Le cordon doit être en mesure d’acheminer un courant 
nominal d’au moins 10 A.

La prise femelle de branchement doit être du type à mise à la 
terre (mise à la masse) et respecter la configuration NEMA 
5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).

Danemark:

La prise mâle d’alimentation doit respecter la section 107-2 D1 
de la norme DK2 1a ou DK2 5a.

Suisse:

La prise mâle d’alimentation doit respecter la norme SEV/ASE 
1011.

Europe

La prise secteur doit être conforme aux normes CEE 7/7 
(“SCHUKO”)

LE cordon secteur doit porter la mention <HAR> ou <BASEC> 
et doit être de type HO3VVF3GO.75 (minimum).

W

ICHTIGE

 S

ICHERHEITSINFORMATIONEN

Stromkabel

. Dies muss von dem Land, in dem es benutzt wird geprüft werden: 

Schweiz

Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen 
einhalten.

Europe

Das Netzkabel muß vom Typ HO3VVF3GO.75 
(Mindestanforderung) sein und die Aufschrift <HAR> oder 
<BASEC> tragen.

Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).

5

Summary of Contents for Baseline 2824

Page 1: ...d link The following figure illustrates one possible configuration Each port has a shielded RJ 45 connector on the front panel Each port is capable of operating at 10 Mbps 100 Mbps or 1000 Mbps The po...

Page 2: ...he connected device does not support auto negotiation the Switch will operate in half duplex mode and therefore can only operate at 10 Mbps or 100 Mbps In such a configuration you may notice some degr...

Page 3: ...y problems in your equipment Rack Mounting or Free Standing This unit can be mounted in a 19 inch equipment rack using the Mounting Kit Refer to Mounting Kit Instructions on page 4 It can also be free...

Page 4: ...holes on one side of the unit refer to the figure following step 6 3 Insert the two screws supplied in the mounting kit and fully tighten with a suitable screwdriver 4 Repeat the two previous steps fo...

Page 5: ...lectrique Il doit tre agr dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen WARNUNG Die Installation und der Ausbau des Ger ts d...

Page 6: ...let is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 In order to meet FCC emissions limits this equipment must be used only with cables which comply wi...

Page 7: ...Finland France Germany Hungary 01 7956 7124 070 700 770 7010 7289 01080 2783 0825 809 622 01805 404 747 06800 12813 Ireland Israel Italy Luxembourg Netherlands Norway Poland 01407 3387 1800 945 3794 1...

Page 8: ...able to locate a copy please contact 3Com and a copy will be provided to you Unless otherwise indicated 3Com registered trademarks are registered in the United States and may or may not be registered...

Reviews: