background image

CONFIGURING 3COM 3C507 AND 3C507TP NIC 

SEPT 11, 1992 [REV. JAN 22, 1993] 

LAN SUPPORT TUTORIAL #3 

PAGE 6 

Add the 3Com Card to the Server Configuration 

After setting the jumpers on the 3C507TP and configuring the card using 3Com's DOS-based 
utility, you must add the card to your server's configuration and build Banyan drivers for 

the card.  

1.  From the Operator Menu at the server console, select System Maintenance. The System 

Maintenance menu will be displayed. 

2.  Select Configure/Diagnose Server from the System Maintenance menu. 

3.  Select the Add-a-card function. 

4.  Select EtherLink 16 from the scrollable list displayed on the Add/Change card screen. 

 

- If any card on the Add/Change card screen is already set at I/O address 100, change the 
card's settings. See the "ICA Card Configuration" instructions below for information about 
changing the ICA card's settings. 

5.  Note all settings on a sheet of a paper. Save the settings by pressing <F10>. Shut the server 

down in the normal fashion. When you reboot, Banyan VINES will build drivers for all the 
cards. 

Configure 3C507 or 3C507TP 

The 3C507 comes with a DOS-based utility from 3Com for configuring the card's resources, 

such as I/O addresses and interrupt levels: if you're installing the card in a CNS server, you 
must configure it in a DOS-based machine prior to installing it in the CNS. If you didn't 

receive the configuration utility on disk with your card, you can download it from 
FsPatches@CTS50@Servers. Filenames for the configuration utilities are 3C507.EXE and 

3C507TP.EXE, respectively. To run the utility, simply type 3C507 or 3c507tp at the DOS 
prompt, and follow the instructions onscreen to accept or change the defaults as needed: 

 

 

 

Recommended Settings 

 

Defaults 

3C507 

3C507TP 

I/O Base Address 

300 

200-3F0, in 10 hex increments 

200-3F0, in 10 hex increments 

Interrupt Level 

Can use 3, 5, 7, 9 10, 11*, 12, or 15 

Can use 3, 5, 7, 9 10, 11*, 12, or 15 

Transceiver Type 

On Board 

External 

Internal 

RAM Base Address 

0d0000 

Can use 0c0000, 0c8000, 0d0000, or 
0d8000 

Can use 0c0000, 0c8000, 0d0000, or 
0d8000 

RAM Size 

64 

use 16 only 

use 16 only 

ROM Base Address 

0c6000 

0c6000 

0c6000 

ROM Size 

Zero wait state 

Disabled 

Disabled 

Disabled 

Data mode 

Turbo 

Turbo 

Turbo 

* The Adaptec SCSI adapter uses interrupt 11 by default. Don't use interrupt 11 if you have 

an Adaptec. 

 

Summary of Contents for 3C507

Page 1: ...r EISA based servers See the C TS Products and Services catalog for details The 3C507 contains a BNC connector for coaxial connection to thinnet networks and an AUI for connection to an external transceiver the 3C507TP has a built in 10BASE T transceiver with an RJ 45 jack for direct connection to twisted pair you ll need a TPAU to connect the 3C507 to TTP telephone twisted pair but you don t for ...

Page 2: ...CONFIGURING 3COM 3C507 AND 3C507TP NIC SEPT 11 1992 REV JAN 22 1993 LAN SUPPORT TUTORIAL 3 PAGE 2 ...

Page 3: ...ress 4 Add the 3C507 or 3C507TP to the Add Change Card screen by selecting 3Com EtherLink 16 from the scrolling list enter the settings for the card see page 4 of this guide 5 Shut down your server normally 6 Open the server case If you changed a previously installed card from I O address 100 and that card requires setting jumper cables on a card remove the card reconfigure the jumpers and reinsta...

Page 4: ...07TP NIC SEPT 11 1992 REV JAN 22 1993 LAN SUPPORT TUTORIAL 3 PAGE 4 FIGURE 1 OVERVIEW OF PROCESS CONFIGURING AND INSTALLING 3C507 AND 3C507TP ye s ye s ye s n o 1 1a 2 3 3a 4 5 7 7a 7b 7aa ye s ye s 6 6a 8 9 9a 10 8a n o n o n o n o ...

Page 5: ... Or set the switches on the Ungermann Bass TPAU that you ll connect to the 3C507 SWITCH SETTINGS FOR ASP300 The Ungermann Bass ASP300 TPAU has only one setting which is for the SQE signal quality error test feature This setting should always be down in order to disable that feature SWITCH SETTINGS FOR UNGERMANN BASS ASP310 AND ASP320 TPAUS FOR USE WITH 3C507 CARD Hub model U B ASM300 U B ASM310 U ...

Page 6: ...igure 3C507 or 3C507TP The 3C507 comes with a DOS based utility from 3Com for configuring the card s resources such as I O addresses and interrupt levels if you re installing the card in a CNS server you must configure it in a DOS based machine prior to installing it in the CNS If you didn t receive the configuration utility on disk with your card you can download it from FsPatches CTS50 Servers F...

Page 7: ...CONFIGURING 3COM 3C507 AND 3C507TP NIC SEPT 11 1992 REV JAN 22 1993 LAN SUPPORT TUTORIAL 3 PAGE 7 ...

Page 8: ... no jumper 8 in the table or on the card this isn t a typo BANYAN ICA CARD JUMPER BLOCK SETTINGS FOR VARIOUS I O ADDRESSES Address Jumper 120 140 160 180 5 down up down up 6 up down down up 7 up up up down 9 up up up up For More Information As many of you know the 10BASE T standard took several years to evolve The standard was finalized by the IEEE in September 1990 which is why different versions...

Reviews: