34
C
HAPTER
2: I
NSTALLING
T
HE
S
WITCH
7700
Connecting the
Ground Wire
To connect the ground wire:
1
Wear an antistatic wrist strap.
2
Remove the screw from the grounding hole in the switch chassis.
3
Set the ground wire connector around the grounding screw.
4
Fasten the grounding screw in the hole on the chassis.
5
Connect the other end of the ground wire to the grounding bar of the switch.
If you install the switch in a cabinet, 3Com recommends that the ground wire of
the switch be connected to the grounding bar of the cabinet.
WARNING:
The resistance between switch chassis and the ground should be less
than 1 ohm.
Connecting and
Configuring Power
The 7-slot and 8-slot chassis offers power modules with one or two power cords.
The power module in the 4-slot chassis has two power cords.
In addition, the 8-slot chassis is available with either AC or DC power modules.
Connecting AC Power
Cords
To connect AC power cords:
1
Power off all the related parts of the switch before connecting the AC power cord
2
Plug the power cord into the socket in the switch and attach the retention clip to
the power cord plug.
3
Plug the other end of the cord into a socket strip with surge protector. Connect
the strip to the power source in the room.
Figure 20 illustrates the single power cord connection for a 7- or 8-slot chassis.
Figure 20
Single Power Cord Connection
1
AC power socket
2
Retention clip
3
Grounding screw
WARNING:
For surge protection, the power should be channelled through an
external protection device into the Switch 7700.
2
1
3
Summary of Contents for 3C16850
Page 6: ......
Page 40: ...40 CHAPTER 2 INSTALLING THE SWITCH 7700 ...
Page 70: ...70 APPENDIX B OBTAINING SUPPORT FOR YOUR SWITCH ...