3Com 3C16750 User Manual Download Page 5

5

Connecting Another OfficeConnect Hub

You may wish to connect another OfficeConnect hub 
to your Dual Speed Hub 8. Alternatively, you may 
wish to add your Hub to an existing 10Mbps 
network. When extending your network, you should 
be aware of the configuration rules given below.

If you connect two Dual Speed Hub 8 units directly 
together, the link between them operates at 100Mbps.

Fast Ethernet (100Mbps) Configuration Rules

The Dual Speed Hub 8 is a Class II hub. You can 
connect directly two Class II Fast Ethernet hubs 
(Class I Fast Ethernet hubs cannot be connected 
directly to other Fast Ethernet hubs). The total length 
of cable (A + B + C below) between two 
workstations, or between a workstation and a 
non-repeater piece of equipment (such as a switch), 
must not exceed 205m (672ft). Each cable (A, B, or 
C) must not exceed 100m (328ft).

3Com recommends that the cable (B) between the 
Fast Ethernet hubs is no longer than 5m (16.4ft). 
This allows the maximum hub-to-workstation cable 
length (A or C) of 100m (328ft) to be used, as shown 
in the example.

Configuration Rules and Example of a Fast Ethernet (100Mbps) Network

Ethernet (10Mbps) Configuration Rules

You can connect a maximum of four Ethernet 
(10Mbps) hubs in series between workstations, or 
between a workstation and a non-repeater piece of 
equipment (such as a switch). Each cable must not 
exceed 100m (328ft). An example is shown below.

Example of Ethernet (10Mbps) Network

Making the Connection to Another Hub

You can connect a 10BASE-T, 100BASE-TX, or 
another 10/100BASE-TX OfficeConnect hub to any 
port on the Dual Speed Hub 8. Use the following 
method:

1

Using a straight-through cable, connect the 
MDI/MDIX port of the Dual Speed Hub 8 to any of 
the ports on the other hub (as shown in the diagram 
below). If using port 8 on the other hub, set its 
MDI/MDIX switch to MDIX (out).

2

Set the MDI/MDIX switch for the MDI/MDIX port on 
the Dual Speed Hub 8 to MDI (in).

Correct Connections for OfficeConnect Hubs

Powering Up and Checking Connections

When you have connected all the appropriate 
workstations and other equipment to the Hub, power 
on the Hub. For each port with a connection, a Port 
Status LED should be on. If the port is operating at 
100Mbps, the corresponding LED in the upper row of 
Port Status LEDs is on. If the port is operating at 
10Mpbs, the corresponding LED in the lower row is 
on. If neither LED is on, check your connections.

CAUTION

:

 Do not power the Hub off and on quickly. 

Wait about 5 seconds between power cycles.

Spot Checks

At frequent intervals, visually check that:

Q

The Alert LED is off — this is the best way to find out 
if there are problems with your network

Q

Case vents are not obstructed

Q

Cabling is secure and not pulled taut

If you suspect a problem, refer to “Problem Solving” 
on page 7.

Summary of Contents for 3C16750

Page 1: ...Hub can be connected to either a 10BASE T Ethernet or a 100BASE TX Fast Ethernet device The port senses the speed of the connected equipment and operates at the appropriate speed If you wish to extend...

Page 2: ...ir TP cable at 100Mbps A Network Loop occurs when two pieces of network equipment are connected by more than one path A Segment is the length of cable connected to a port Packets are the units of info...

Page 3: ...0BASE TX or 10 100BASE TX connections must be data grade Category 5 Your supplier should stock suitable cables The maximum length of a single cable is 100m 328ft Refer to Fast Ethernet 100Mbps Configu...

Page 4: ...it over the screw heads When in line gently push the unit on to the wall and move it downwards to secure When making connections be careful not to push the unit up and off the wall Connecting Workstat...

Page 5: ...e of equipment such as a switch Each cable must not exceed 100m 328ft An example is shown below Example of Ethernet 10Mbps Network Making the Connection to Another Hub You can connect a 10BASE T 100BA...

Page 6: ...is must be approved for the country where it is used USA and Canada The cord set must be UL approved and CSA certified The minimum specification for the flexible cord is No 18 AWG Type SV or SJ 3 cond...

Page 7: ...tween the Hub and another OfficeConnect hub not working Check your connections follow the information given in the Connecting Another OfficeConnect Hub section on page 5 It is likely that an MDI MDIX...

Page 8: ...ES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF...

Reviews: