The Office
Connect® Hub 8/T
PM has been designed
to aid you when detecting and solving possible
problems with your network. These problems are
rarely serious, the cause is usually a disconnected or
damaged cable, or incorrect configuration. If this
chapter does not solve your problem, contact your
supplier for information on what to do next.
Perform these actions first:
■
Ensure all equipment is powered on.
■
Power each hub off, wait about 5 seconds and then
power them on so they perform a self-test. The
self-test only takes a few seconds, during which all
LEDs light. Port Status LEDs light yellow.
Isolating a Problem
A good way of isolating a problem is to see whether
it occurs on a particular port only. This can be done
by:
■
Using a different port to see if the problem still exists.
■
Using management to view how a port has been set
up. In particular, see if the port is:
■
Partitioned because of a network loop
■
Disabled by management
■
Part of a resilient link pair
■
Performing security
Check the Alert LED and if lit, use the Alerts dialog
box in Quick Config Manager to see what condition
is causing it to light.