3Com Baseline Switch 2800 Family 

(3CBLUG16A, 3CBLUG24A) 

  

User Guide  

 

 

Summary of Contents for 2800 Series

Page 1: ...i 3Com Baseline Switch 2800 Family 3CBLUG16A 3CBLUG24A User Guide...

Page 2: ...1 Powering On 13 3 Problem Solving 14 4 Obtaining Support For Your Product 16 Register Your Product to Gain Service Benefits 16 Purchase Value Added Services 16 Troubleshoot Online 17 Contact Us 17 Te...

Page 3: ...guran a importantes 31 Appendix B Regulatory Information 34 FCC Statement 34 Information to the User 34 CE Statement Europe 35 ICES Statement 35 VCCI Statement 36 Appendix C Collection List of the Haz...

Page 4: ...witching but do not need sophisticated management functions The Switch is shipped ready for use Operational straight out of the box No configuration is necessary Your 3Com Baseline Switch incorporates...

Page 5: ...e if they have been priority encoded When a packet is received the Switch will read the priority level and determine the appropriate channel to forward the packet based on the priority level This feat...

Page 6: ...lded RJ 45 data sockets They cannot be used as standard traditional telephone sockets or to connect the unit to a traditional PBX or public telephone network Only connect RJ 45 data connectors network...

Page 7: ...4 Physical Features Front Panel Figure 1 2 2816 Figure 1 3 2824 Rear Panel Figure 1 4 Rear Panel...

Page 8: ...ontact your supplier Link Activity Green The port works at the rate of 1000 Mbps the LED flashes quickly when the port is sending or receiving data Yellow The port works at the rate of 10 or 100 Mbps...

Page 9: ...1 75 kg Ethernet port 16 24 Mounting Free standing or 19 inch rack mounted using the mounting kit supplied Electrical Power Inlet IEC 320 AC Input Voltage Rating Rated voltage range 100 240V AC 50 60...

Page 10: ...4 Network Design The Switch provides high performance switched connections to 10 Mbps 100 Mbps and 1000 Mbps hubs switches servers and workstations that need a dedicated switched link The following fi...

Page 11: ...8 Figure 1 5 Network Design...

Page 12: ...mationen Bevor Sie Komponenten aus dem Switch entfernen oder den Switch hinzuf gen oder Instandhaltungsarbeiten verrichten lesen Sie die Sicherheitsanweisungen die in Anhang A in diesem Handbuch aufge...

Page 13: ...forma es de seguran a no Appendix A Safety Information deste guia Package Contents The switch packaging contains the following for all units One product sealed in a plastic bag One power cord for use...

Page 14: ...ature around the switch does not exceed 40 C 104 F If the switch is installed in a 19 inch rack or closed assembly its local air temperature may be greater than room ambient temperature The air is as...

Page 15: ...ruct the air flow through the side panels of the switch To rack mount the switch 1 Place the switch the right way up on a hard flat surface with the front facing towards you 2 Locate a securing bracke...

Page 16: ...ure with suitable screws Ensure that ventilation holes are not obstructed 6 Reconnect network cables Powering On The following sections describe how to get the switch powered up and ready for operatio...

Page 17: ...problem with this connection Check that 1 The device being connected to is powered on and operating correctly 2 The cable is connected at both ends 3 You are using a Twisted Pair cable that is not dam...

Page 18: ...t still does not operate successfully contact your supplier with the following information before returning the unit 1 Product number and serial number printed on a label supplied with the unit 2 A br...

Page 19: ...Registration Repair Services and Service Request If you have trouble registering your product please contact 3Com Global Services for assistance Purchase Value Added Services To enhance response time...

Page 20: ...hone Technical Support and Repair To enable telephone support and other service benefits you must first register your product at http eSupport 3com com Warranty and other service benefits start from t...

Page 21: ...0 933 486 Or use the following numbers India 61 2 9424 5179 or Austria 01 7956 7124 000800 650 1111 Belgium 070 700 770 Indonesia 001 803 61009 Denmark 7010 7289 Japan 00531 616 439 or Finland 01080 2...

Page 22: ...800 998 2112 Nicaragua AT T 800 998 2112 Bonaire 1 800 998 2112 Panama AT T 800 998 2112 Brazil 0800 13 3COM Paraguay 54 11 4894 1888 Cayman 1 800 998 2112 Peru AT T 800 998 2112 Chile AT T 800 998 21...

Page 23: ...wall plug must have a configuration for mating with an EN60320 IEC320 appliance inlet The socket outlet must be near to the unit and easily accessible You can only remove power from the unit by disco...

Page 24: ...t be UL approved and CSA certified The minimum specifications for the flexible cord is No 18 AWG Type SV or SJ 3 conductor The cord set must have a rated current capacity of at least 10A The attachmen...

Page 25: ...e d appareil EN60320 IEC 320 La prise secteur doit se trouver proximit de l appareil et son acc s doit tre facile Vous ne pouvez mettre l appareil hors circuit qu en d branchant son cordon lectrique a...

Page 26: ...oit avoir re u l homologation des UL et un certificat de la CSA Le cordon souple doit respecter titre minimum les sp cifications suivantes calibre 18 AWG type SV ou SJ 3 conducteurs Le cordon doit tre...

Page 27: ...Ger teeingang haben Die Netzsteckdose mu in der N he des Ger ts und leicht zug nglich sein Die Stromversorgung des Ger ts kann nur durch Herausziehen des Ger tenetzkabels aus der Netzsteckdose unterb...

Page 28: ...evarla a cabo personal cualificado Si instala la unidad Switch en una pila con unidades Baseline el Switch se debe instalar debajo de las unidades Hub m s estrechas La unidad debe tener toma de tierra...

Page 29: ...ctamente a tierra Imp dance la terre Son conectores de datos RJ 45 blindados No pueden utilizarse como tomas de tel fono tradicionales est ndar ni para conectar la unidad a una central de conmutaci n...

Page 30: ...13 A e instalarse con un fusible de 13 A que cumpla BS1362 El cable de alimentaci n de red debe tener la marca HAR o BASEC y ser de tipo H03VVF3G1 0 m nimo S lo para Europa La toma de alimentaci n de...

Page 31: ...nelle stesse condizioni Solo per Francia e Per Questa unit non pu ricevere alimentazione di tipo IT Se l alimentazione di tipo IT l unit deve essere alimentata a 230 V 2P T tramite un trasformatore di...

Page 32: ...deve essere contrassegnato dai marchi HAR o BASEC ed essere di tipo H03VVF3G1 0 minimo Solo Europa La spina di alimentazione deve essere conforme CEE 7 7 tipo SCHUKO Il cavo dell alimentazione di rete...

Page 33: ...e mo e by zasilane zasilaczem IT Je li zasilacze s typu IT urz dzenie to musi by zasilane napi ciem 230V 2P T z transformatora separuj cego 1 1 a drugi bolec wtyczki musi by oznaczony jako Neutral i m...

Page 34: ...ci zasilaj cej musi by oznaczony HAR lub BASEC i musi by typu H03VVF3g1 0 minimum Europa Wtyczka zasilaj ca musi by zgodna z norm CEE 7 7 SCHUKO Przew d sieci zasilaj cej musi by oznaczony HAR lub BAS...

Page 35: ...nas mesmas condi es apenas para Fran a e Peru Esta unidade n o pode ser energizada a partir de fonte de alimenta o IT Se a alimenta o for do tipo IT a unidade deve ser energizada em 230V 2P T por meio...

Page 36: ...de alimenta o deve estar de acordo com o padr o BS1363 3 pinos 13 amp equipado com fus vel de 13A de acordo com o padr o BS1362 O cabo de alimenta o deve estar identificado com HAR ou BASEC e ser do t...

Page 37: ...se the user will be required to correct the interference at their own expense Information to the User If this equipment does cause interference to radio or television reception which can be determined...

Page 38: ...h the European Low Voltage Directive 2006 95 EC and EMC Directive 2004 108 EC Warning This is a class A product In a domestic environment this product may cause radio interference in which case the us...

Page 39: ...36 VCCI Statement...

Page 40: ...b Hg Cd Cr VI PBB PBDE PCBA HASL Solder Joint and surface finish on PCBA Lead frame s base materials and surface finishes with copper alloy of electronic components Solders in electronic components or...

Page 41: ...his collection list is made in compliance with both the Administrative Measures on the Control of Pollution Caused by Electronic Information Products 28 Feb 2006 and the Marking for the Control of Pol...

Page 42: ...EC 2005 747 EC 2006 310 EC 2006 690 EC 2006 691 EC and 2006 692 EC SJ T 11363 2006 RoHS 2002 95 EC The sign indicates that the marked substance complies with both the Requirements for Concentration L...