background image

2

The numbers in this diagram refer to numbered sections in the 
text.

Front Panel

1 24 RJ-45 10/100 Ports

WARNING

: RJ-45 ports.

 These are shielded RJ-45 data 

sockets. They cannot be used as standard traditional 
telephone sockets, or to connect the unit to a traditional 
PBX or public telephone network. Only connect RJ-45 
data connectors, network telephony systems, or network 
telephones to these sockets. Either shielded or 
unshielded data cables with shielded or unshielded jacks 
can be connected to these data sockets.

 

 

AVERTISSEMENT: Les ports RJ-45.

 Ceux-ci sont 

protégés par des prises de données. Ils ne peuvent pas 
être utilisés comme prises de téléphone conventionnelles 
standard, ni pour la connection de l’unité à un réseau 
téléphonique central privé ou public. Raccorder 
seulement  connecteurs de données RJ-45, systèmes de 
réseaux de téléphonie ou téléphones de réseaux à ces 
prises. Il est possible de raccorder des câbles protégés ou 
non protégés avec des jacks protégés ou non protégés à 
ces prises de don.

 

 

WARNUNG: RJ-45-Porte

. Diese Steckdose sind 

geschützte Datensteckdosen. Sie dürfen weder wie 
normale traditionelle Telefonsteckdosen noch für die 
Verbindung der Einheit mit einem traditionellem 
privatem oder öffentlichem Telefonnetzwerk gebraucht 
werden.  Nur RJ-45-Datenanscluße, Telefonnetzsysteme 
or Netztelefone an diese Steckdosen anschließen. 
Entweder geschützte oder ungeschützte Buchsen dürfen 
an diese Datensteckdosen angeschlossen werden.

 

 

ADVERTENCIA: puertos RJ-45

. Son conectores de 

datos RJ-45 blindados. No pueden utilizarse como tomas 
de teléfono tradicionales estándar ni para conectar la 
unidad a una central de conmutación PBX tradicional ni 
a una red telefónica pública. Conecte sólo conectores de 
datos RJ-45, sistemas de telefonía de red local o 
teléfonos de red local a estas tomas. Es posible conectar 
cables de datos blindados o sin blindar con clavijas 
blindadas o sin blindar a estos conectores de datos.

The Switch has 24 10/100 Mbps auto-negotiating ports. To 
connect a device to the Switch, use Category 5 unshielded or 
shielded (screened) 100 Ohm TP cable (or Category 3 cable for a 

10 Mbps connection). The maximum length of cable for each 
connection is 100m (328ft). Connect one end of the cable to an 
RJ-45 port on the Switch, and the other end to the appropriate 
RJ-45 port on the connecting device.

Each port on the Switch is auto-negotiating: its speed and 
duplex mode (half duplex or full duplex) are automatically 
determined by the capabilities of the connected device. 

Each port supports automatic MDI/MDI-X detection and can be 
connected to either a 10BASE-T or a 100BASE-TX device.

I

f you connect two Switch units together, the link 

between them operates at 100 Mbps full duplex. You 
must use Category 5 cable when connecting the units.

CAUTION: 

The Switch supports full duplex 

auto-negotiation. If the connected device does not 
support auto-negotiation, the Switch will operate in half 
duplex mode (even if the device is operating in full 
duplex mode). In such a configuration, you may notice 
some degradation of network performance. 3Com 
recommends that you use devices that are capable of 
auto-negotiation (and that you ensure that 
auto-negotiation is enabled, if it is a configurable 
option).

2 Two 10/100/1000BASE-T Ports

Ports 25 and 26 are Gigabit RJ-45 ports. These 1000BASE-T 
RJ-45 ports support automatic MDI/MDI-X operation, so you can 
use either straight-through or crossover cables for all network 
connections to workstations or servers, or to other switches or 
hubs.

Use Category 5e cables for 1000BASE-T operation.

3 Activity/Link/Speed Status LEDs

The first (top) and third row of LEDs, which are colored yellow or 
green, show the activity and speed status of the related ports:

P

HYSICAL

 F

EATURES

!LLPORTSARE!UTO-$)-$)8

 

0ORT

#

"ASELINE

3WITCH'

 

6^(Z!

Status

Meaning

On

The link has been established.

Flashing

Packets are being received or transmitted on the port.

Off

If the link has not been established, either nothing is 
connected to the port, or there is a problem:

Check that the attached device is powered on.

Check that the cable is the correct type and is not faulty.

If these checks do not identify the cause of the problem, it 
may be that the unit or the device connected to the port is 
faulty. Contact your supplier for further advice.

!

Summary of Contents for 2126-G - Baseline Switch

Page 1: ...omatic MDI MDI X detection The Switch is suitable for office use where it can be free standing or rack mounted in a wiring closet or equipment room The Switch comes with One power cord for use with the Switch Four self adhesive rubber pads One mounting kit The Switch provides high performance switched connections to 10 Mbps and 100 Mbps hubs servers and workstations that require a dedicated switch...

Page 2: ...gory 5 unshielded or shielded screened 100 Ohm TP cable or Category 3 cable for a 10 Mbps connection The maximum length of cable for each connection is 100m 328ft Connect one end of the cable to an RJ 45 port on the Switch and the other end to the appropriate RJ 45 port on the connecting device Each port on the Switch is auto negotiating its speed and duplex mode half duplex or full duplex are aut...

Page 3: ...ossen werden können Die Kabel nicht in der nähe von elektrischen Störquellen befinden Das schließt Aufzugsschächte Mikrowellen und Klimaanlagen ein Elektromagnetische Felder können die Signale in den Kupferleitungen stören und Fehler verursachen was die Verlangsamung Ihres Netzwerkes zur Folge haben kann Weder Wasser noch Feuchtigkeit in das Gehäuse eindringen kann Die Luftzirkulation um den Switc...

Page 4: ...neten Schraubendreher fest 4 Widerholen Sie letzten beiden Schritte auf der anderen Seite der Baugruppe 5 Führen Sie die Baugruppe in den 19 Zoll Baugruppenträger ein und sichern sie die Baugruppe mit geeigneten Schrauben Nicht im Lieferumfang enthalten 6 Schließen Sie alle Kabel wieder an Refer to the information about LEDs given earlier in this guide to see if the problem can be identified and r...

Page 5: ...t 1 1 avec un point secondaire de connexion portant l appellation Neutre et avec raccordement direct à la terre masse Cordon électrique Il doit être agréé dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen WARNUNG Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen Wenn der Switch 2016 2024 mit andere...

Page 6: ...quency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference to radio communications in which case the user will be required to correct the interference at their own expense Information to the User If this equipment does cause interfere...

Page 7: ...om support engineers Connection Assistant helps you install configure and troubleshoot 3Com desktop and server NICs wireless cards and Bluetooth devices This diagnostic software is located at http www 3com com prodforms software conne ction_assistant ca_thankyou html Access Software Downloads Software Updates are the bug fix maintenance releases for the version of software initially purchased with...

Page 8: ...r respective holders Country Telephone Number Country Telephone Number Asia Pacific Rim Telephone Technical Support and Repair Europe Middle East and Africa Telephone Technical Support and Repair Australia Hong Kong India Indonesia Japan Malaysia New Zealand Pakistan Philippines P R of China Singapore S Korea Taiwan Thailand 1 800 678 515 800 933 486 61 2 9424 5179 or 000800 650 1111 001 803 61009...

Page 9: ...osal of all end of life electronic components Regulated Materials Statement 3Com products do not contain any hazardous or ozone depleting material Enviromental Statement about the Documentation The documentation for this product is printed on paper that comes from sustainable managed forests it is fully biodegradeable and recyclable and is completely chlorine free The varnish is enviromentally fri...

Reviews: