For the LANplex 2500/2016

 

Module Description

 

This module contains eight (8) unterminated Ethernet 10BASE-2 ports that 
use BNC connectors. I

 

f a port on this module is at the end of a 10BASE-2 

(BNC) segment, you must provide an external 50 Ohm terminator. 

 

When the port is at the end of a segment, using a T connector with a 
terminating plug may cause interference with adjacent ports. 3Com 
recommends terminating ports with the ITT Pomona Y connector, Model 
4896, with a terminating plug on the end, or the ITT Pomona Feed-Thru 
Terminator, Model 4119-50. When the port is in the middle of a segment, the 
Y connector may be necessary. 

Prior to installing the unterminated 10BASE-2 (BNC) module, LANplex 
system software revision 7.0.0 or later and LANplex diagnostics software 
revision 3.0.2 or later must be installed. A system software revision 
supporting this module is available from the 3com BBS, the Internet FTP site 
(3Com.ftp.com), or 3Com Forum on Compuserve, or 3Com’s Web site 
(http://infodeli.3com.com/infodeli/swlib/switch_files.htm).

 

For a description of how to configure this module into your network, see 
the LANplex documentation set.

 

Audience

 

This guide is intended for trained technical personnel only. 

Port Status

Unterminated

1

2

3

4

5

6

7

8

Active
Error

Board
Error

 

 

R

Summary of Contents for 10BASE-2 (BNC

Page 1: ...TT Pomona Feed Thru Terminator Model 4119 50 When the port is in the middle of a segment the Y connector may be necessary Prior to installing the unterminated 10BASE 2 BNC module LANplex system software revision 7 0 0 or later and LANplex diagnostics software revision 3 0 2 or later must be installed A system software revision supporting this module is available from the 3com BBS the Internet FTP ...

Page 2: ...fore you install your new module follow the appropriate pre installation instructions in this section Read if initial installation Your LANplex system is shipped with protective faceplates covering the exposed installation slots You must remove the protective faceplate covering the selected installation slot prior to installing the option module CAUTION When handling modules 3Com recommends that y...

Page 3: ...aptive screws securing the module to the chassis 3 Pull the module out of the chassis The following figures show termination of unterminated BNC ports using either a Y connector or a Feed thru terminator Captive screw Faceplate Power Run Processor Power Fan Temp Config Inserted ERROR PCMCIA LANplex 2500 R Captive screw Y terminator Unterminated 10BASE 2 BNC option module Green Active Yellow Error ...

Page 4: ...module do not insert any metal objects such as a screwdriver or a finger wearing jewelry in the open slot This could cause burns or other bodily harm 3 Place the module between the guides of the selected slot and slide the module into the chassis See the figure below Feed thru terminator Unterminated 10BASE 2 BNC option module Green Active Yellow Error Board Error Port Status Active Error 1 2 3 4 ...

Page 5: ...cure the module in the chassis Once the module is installed see Chapter 4 Cabling the System in your Getting Started guide for information on cabling the module to the network Option Module Diagnostics Module diagnostics run at power up or when replacing a module with the power on During diagnostics the module s port status Error LEDs are lit yellow When diagnostics are successfully completed the ...

Page 6: ...fication of such revision or change 3Com Corporation provides this documentation without warranty of any kind either implied or expressed including but not limited to the implied warranties of merchantability and fitness for a particular purpose 3Com may make improvements or changes in the product s and or the program s described in this documentation at any time 3Com and LANplex are registered tr...

Reviews: