3Com 1000BASE-SX GBIC Quick Start Manual Download Page 20

Summary of Contents for 1000BASE-SX GBIC

Page 1: ...nd other IEEE 802 3z compliant Gigabit Ethernet devices Key Features The GEN Interface Modules support the following key features Two front panel IEEE 802 3z compliant Gigabit Ethernet fiber optic por...

Page 2: ...erface Modules Each GEN Interface Module has two ports on the front see Figure 1 as well as two ports on the rear of the module not shown in Figure 1 that connect to the chassis backplane Because the...

Page 3: ...on when you install remove or replace a GEN Interface Module When the system is on never insert metal objects such as a screwdriver or a finger with jewelry into open module slots When the system is o...

Page 4: ...r otherwise force the module into the chassis when you insert it into the module slot guides Before you push the module into the chassis make sure that the module ejector handles are open To slide the...

Page 5: ...y the front panel only Do not touch any components pins leads or solder connections If the module appears to be damaged replace it in its antistatic bag and shipping box and contact your supplier Inst...

Page 6: ...k Start Guide Enterprise Management Controller Quick Start Guide 2 Switch Fabric Modules Because you manage a GEN Interface Module through the primary GEN Switch Fabric Module you must install one GEN...

Page 7: ...e performance install the module in slot 1 2 3 4 5 6 7 10 11 or 12 3Com recommends that you do not install the module in slot 13 14 15 or 16 because these slots only have one connection to the backpla...

Page 8: ...le Port Numbers SFM Backplane Port Numbers Assigned to Chassis Slot SFM LED Numbers Assigned to Backplane Port Numbers 1 4 only 2 are accessed by this module 1 2 1 2 1 2 2 4 only 2 are accessed by thi...

Page 9: ...e Module Port Numbers SFM Backplane Port Numbers Assigned to Chassis Slot SFM LED Numbers Assigned to Backplane Port Numbers 1 2 1 2 1 2 1 2 2 2 1 2 3 4 3 4 3 2 1 2 5 6 5 6 4 2 1 2 7 8 7 8 5 2 1 2 9 1...

Page 10: ...e Empty slots must be covered to ensure proper air flow and cooling in the chassis 4 Open the module ejector handles 5 Begin to insert the module In the 7 slot chassis hold the module horizontally wit...

Page 11: ...TA T SE C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3CB9FG24 PR I M O D S TA T SE C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3CB9FG24 PR I M O D S TA T SE C...

Page 12: ...SE C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3CB9FG24 PR I M OD ST AT SE C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3CB9FG24 PR I M OD ST AT SE C 1 2 3 4 5...

Page 13: ...assis or installed beneath this module in a 7 slot chassis you may need to apply sideways or downward pressure on that adjacent module to have your module line up correctly in its slot Applying this p...

Page 14: ...test both the Module Status and Port Status LEDs flash for approximately 1 second and then reflect the active status of the module as described in Table 3 Table 3 Module and Port Status LED Indicators...

Page 15: ...ide To manage GEN Interface Module ports from the Administration Console 1 Log in to the EME For information about logging in to the EME see the CoreBuilder 9000 Enterprise Management Engine User Guid...

Page 16: ...tions 800 743 2675 fax 828 327 5973 The following table lists the part number information Fiber Type Modal Bandwidth MHz km Segment Length 62 5 125 microns MMF 160 Up to 220 m 722 ft 62 5 125 microns...

Page 17: ...torage humidity 10 to 95 relative humidity noncondensing Module Dimensions Weight 1000BASE SX 3CB9LG2MC 2 54 cm x 38 81 cm x 33 50 cm 1 in x 15 28 in x 13 19 in 1 81 kg 4 85 lb 1000BASE LX 3CB9LG2SC 2...

Page 18: ...e system see the following documents CoreBuilder 9000 Enterprise Switch Getting Started Guide 16 Slot Chassis Quick Installation Guide for the CoreBuilder 9000 Enterprise Switch 7 Slot Chassis Quick I...

Page 19: ......

Page 20: ......

Page 21: ...f the software products will be uninterrupted or error free or that all defects in the software products will be corrected For any third party products listed in the 3Com software product documentatio...

Page 22: ...OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND SATISFACTORY QUALITY 3COM NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT A...

Page 23: ...iance This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment rad...

Page 24: ...e to time without obligation on the part of 3Com Corporation to provide notification of such revision or change 3Com Corporation provides this documentation without warranty term or condition of any k...

Reviews: