3A HEALTH CARE MYNEB Instruction Manual Download Page 6

10

DIsPOsAl PROCEDURE (Dir. 2012/19/Ue-WEEE) The symbol on the bottom of the device indicates the 
separated collection of electric and electronic equipment. At the end of life of the device, do not dispose 
it as mixed solid municipal waste, but dispose it referring to a specific collection centre located in your 

area or returning it to the distributor, when buying a new device of the same type to be used with the same 
functions. This procedure of separated collection of electric and electronic devices is carried out forecasting a 
European environmental policy aiming at safeguarding, protecting and improving environment quality, as well as 
avoiding potential effects on human health due to the presence of hazardous substances in such equipment or 
to an improper use of the same or of parts of the same. Caution! The wrong disposal of electric and electronic 
equipment may involve sanctions.

TECHNICAl sPECIFICATIONs
Nebulisation rate: 

0.45 ml/min. (NaCI 0.9%)

Particle size: 

75% < 5 µm NaCI 0.9%
3.11 µm (MMD with 0.9% NaCI using Cascade Impactor)

Compressor air flow: 

12 l/min.

Acoustic noise level:  

51 dB

Power source: 

12V DC 2A

AC adapter: 

Input: 100-240VAC 50/60Hz 0.6A 

Output: 12V DC 2A

Nebuliser capacity: 

min. 2 ml; max. 16 ml

Operating limits: 

30 min. On / 30 min. Off

MDD 93/42/EEC 
Class of risk: 

IIa

Weight: 

approx. 450 g

Dimensions: 

132(L) x 140(W) x 60(H) mm 

Expected service life: 

5 years 

Technical alterations reserved.

Operating Temperature/Humidity: +10° C to +40° C / 10% to 95% RH
Storage and Transport Temperature/Humidity/Air Pressure: –25° C to +70° C     / 10% to 95% RH      / 690 - 
1060hPa

3A HEAlTH CARE s.r.l.

Via Marziale Cerutti, 90F/G
25017 Lonato del Garda (BS) - ITALY

Conforms to Directive 93/42/EEC for medical devices

sYMBOls

Type BF device

Alternating current

 Class II

Do not use the unit when taking a bath or a shower

Switch “OFF”

It is compulsory to carefully read the instructions

before using this device

Switch “ON”

The device’s casing is protected against solid particles having diameter 

of 12.5 mm or above, vertically falling water drops and access to

hazardous parts with a finger.

Summary of Contents for MYNEB

Page 1: ...INSTRUCTION MANUAL MYNEB ...

Page 2: ...1e 1a 1d 1c 1 1d 4 3 6 8 7 2 5 6 4 5 3a 3 3b 4a 3b 2 1 3 4 A B 1a 1b 1a Fig Abb A Fig Abb C Fig Abb E Fig Abb F Fig Abb G Fig Abb B Fig Abb D ...

Page 3: ...me temperatures impact and dropping contamination and dust direct sunlight heat and cold Only use the medication prescribed for you by your doctor and follow your doctor s instructions with regard to dosage duration and frequency of the therapy All accessories should only be used by one person Never bend the nebuliser over 60 The unit should not be used in the presence of anesthetic mixture inflam...

Page 4: ... the section Cleaning and Disinfecting This device was designed for intermittent use of 30 min On 30 min Off Switch off the device after 30 min use and wait for another 30 min before you resume treatment FASTERJET NEBULIZER fig E This compressed air system for aerosoltherapy is equipped with the innovative Fasterjet nebuliser with a breath en hanced valve system This enables the correct quantity o...

Page 5: ...ssembled and the vaporiser head 3a is placed correctly Fig B Ensure the required medication has been added Fig D GUARANTEE This device is covered by a 3 year guarantee from the date of purchase The guarantee is valid only on presentation of the guarantee card completed by the dealer see back conforming date of purchase or the receipt The guarantee covers only the compressor The replaceable compone...

Page 6: ...tion rate 0 45 ml min NaCI 0 9 Particle size 75 5 µm NaCI 0 9 3 11 µm MMD with 0 9 NaCI using Cascade Impactor Compressor air flow 12 l min Acoustic noise level 51 dB Power source 12V DC 2A AC adapter Input 100 240VAC 50 60Hz 0 6A Output 12V DC 2A Nebuliser capacity min 2 ml max 16 ml Operating limits 30 min On 30 min Off MDD 93 42 EEC Class of risk IIa Weight approx 450 g Dimensions 132 L x 140 W...

Page 7: ...chio difettoso Sono esclusi dalla garanzia danni causati da usi impropri incidenti o mancanza di cure opportune This warranty certificate is valid only if returned to your dealer along with Receipt and Faulty Unit Warranty does not cover damages caused by misuse crashes or lack of attention DESCRIZIONE GUASTO FAULT DESCRIPTION Data di vendita Date of purchase Rivenditore timbro e firma Dealer Stam...

Page 8: ...24 3A HEALTH CARE S r l Via Marziale Cerutti 90F G 25017 Lonato del Garda BS ITALY 3A3937 rev 00 01 2018 ...