PLUMBING RECOMMENDATIONS:
To prevent excess fertilizer from dribbling out of the hoses
when product application is shut off , install one push to
connect polypropylene (Inlet x Outlet) 3/8” O.D. check valve
(not included) in the plumbing to each row prior to the 360
BANDIT orifi ces. Check valve is available at Dultmeier Sales
(Item #BUCV1103-P38).
A 50 mesh strainer (not included) can be used in the
complete plumbing system between tanks and 360
BANDIT to help prevent debris from blocking orifi ces.
16
17
18
19
Install orifi ce plates
16
in the rubber grommets
17
.
Assemble pluming components in the arrangement shown
above
18
.
Attach the plumbing assembly to each of the hoses coming
from the house guides
19
.
NOTE: If hoses are not fully seated in the push to connect,
they will leak. Hoses seat 7/8” of an inch deep or until you
hear a snap.
The supplied push to connect adapter in the 360 BANDIT
kit connects to 3/8” push to connect compatible hose.
Secure hoses to row unit with provided zip ties.
INSTALLATION INSTRUCTIONS
GREAT PLAINS
STEP 6
ASSEMBLE PLUMBING
INSTALLATION COMPLETE
PAGE 4