6. INSTALLATION
6.1-3 CEILING INSTALLATION
Ceiling installation of
SAVANA
Heat units is made on
threaded rods M8. Threaded rods are optional acces-
sories and must be ordered separately
For any manipulation with the heater unit, protective
gloves must be used to avoid injury by sharp edges.
6.1-3.1 Allocate the ceiling
installation point
6.1-3.2 Install the unit on the ceiling
must be fixed firmly to the ceiling! Use quality
connecting material for anchoring!
B
A
Type
A
B
SAV-2
508
483
SAV-4
708
683
SAV-6
808
783
Dimensions in the table are in mm
4x 10