background image

14

2VV.

 Creating innovative solutions for you and your business since 1995.

8. WIRING DIAGRAM

VCS-R4-SU-E-MA-AC

2

N

áz

ev

: V

C

S-R

4-S

U

-E

-M

A-A

C

M

O

DRÁ

BÍLÁ

1

6
7

8

2

3

4

5

1

R

UDÁ

4

6

8

7

5

3

Fir

m

a: 2

VV

FUSE

R

O

OM

W

AT

R

O

O

M

O

U

TS

ID

E

CO
NT

RO
L P

AN

EL

N

DC12V

PE

PW
M

RELAY

NO
T

H

EAT

D

O

O

R

THE
R

M

EXT

RUN

U

SE

D

0-1

0V

R

OOM

RELAY

RELAY

G

ND

+

1234

56

78

9

11

10

12

13
14
15
16
17
18
19
20
21
22
23
24

IN

-1

IN

-2

L

L
 H

1
 H

2

ERR.

AL

ARM

 H

EA

T

L

L

Fu

5758

59

6061

62

31

56
55
54
53
52
51
50

48

49

47
46
45
44
43
42

27 28 29 30

25 26

W

.P

UM
P

I-B

US

OU
TP

U

T

JT

AG

JP4
JP3

JP2
JP1

CA
N

L

CA
N

H

GN
D

+1

2V

B

A

PW
M

N

O

T

U

SED

RE
F.

-O

UT

NO
T

U

SED

INL

ET

AI

R

O

U

TL

ET

AIR

NO
T

U

SE

D

RELAY

RELAY

zdr

oj

 1

2V

+

-

NL

1

2

3

Out

AC

3-

v1

SSR

4

1

2

3

SSR

4

1

3

2

NTC 10K

CANL

CANH

GND

+12V

B

A

SD

SLOT

4

65 66

63 64

GN
D

+1

2V

B

A

8

7

6

5

4

3

2

1

3

2

1

NTC 10K

Č

ísl

o  

: 2

-6

02

-S

11

67

0

1

5

33

36

37

40

28

41

15

23

12

13

14

11

24

9

10

22

Zkrátit 350mm

16

21

34

35

38

39

42

Kre

sl

il: K

on

va

lin

a

D

atu

m

: 2

7.1

1.2

019

Ve

rze

: 1

4

3

2

6

7

8

Summary of Contents for FINESSE

Page 1: ...FINESSE STANDESSE SUPERIOR control Installation instruction EN v 1 20 05 20 ...

Page 2: ......

Page 3: ...od order In case of doubt contact the vendor Do not install a damaged unit If you will not unpack the product immediately after de livery store it indoors in a dry place with ambient tem peratures between 5 C and 40 C PACKAGE CONTENTS 5 o C 40 o C All the packaging material is environmentally friendly and can be reused or recycled Contribute actively to the protection of the environment and ensure...

Page 4: ...ím a musí být objednávány zvlášť vá clona je připojena k řídícímu modulu Rychlých připojovacích konektorů žte řídící modul do vzduchové clony 17 STALACE Vzduchová clona musí být chráněna vhodným jističem v souladu s jeho elektrick Z bezpečnostních důvodů se nedoporučuje předimenzovaná ochrana Vzduchová clona musí bý zapojena pomocí systému TN S což znamená že neut být vždy zapojený Hlavní spínač v...

Page 5: ...usiness since 1995 1 2 3 4 5 6 CANL 30 CANH 29 12V 27 GND 28 1 INSTALLATION 1 2 CONNECTING THE CONTROL Connection to the regulation control panel and accessories 3 a b c d Connect the remote control and accesso ries to the terminals on the electronic board ...

Page 6: ... 16 2 3 4 7 12 13 14 8 9 10 PL IT CS Układ mieszający zasilanie Punto di miscelazione alimentazione SMU napájení Sygnał sterujący do nastawienia SMU heater cooler Segnale di controllo impostabile SMU heater cooler Řídící signál nastavitelné SMU heater cooler Czujnik przestrzenny Sensore ambientale Prostorové čidlo teploty GND GND R CE RAL ERROR ttable DX DEFROST settable GND 2 1 V 0 10 VDC CO2 RH ...

Page 7: ...4 CONTACT EXTERNE ON OFF CONTACT INCENDIE CMSI 62 61 BOOST BOOST 57 58 boitier de commande J1 J2 20 21 22 23 24 7 76 75 74 73 25 26 27 28 29 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 31 33 35 36 37 38 39 40 41 42 43 9 44 45 46 47 48 49 50 30 32 34 72 71 70 69 LO N GND GND 0 10V SSR SSR GND 0 10V 230VAC W PUMP ALARM HEATER RUN OUTPUT COOL HEAT HEAT PUMP HEAT PUMP ERROR DEFROST EXTERNAL ...

Page 8: ...ASTER SLAVE no 1 The total length of all chained air curtains must not exceed 150 m ELECTRICAL DRAWINGS CHAINING SLAVE no 2 SLAVE no 10 SLAVE SLAVE MASTER A A A A B B B B GND GND GND GND SLA VE no 1 1 no 2 2 no 3 3 no 4 4 no 5 5 SLA VE no 6 6 no 7 7 no 8 8 no 9 9 no 10 A SLAVE A B GND ...

Page 9: ...break or switching contact CAUTION Not included with the product 2 1 2 DK 1 DK B3 door contact TECHNICAL INFORMATION Isolated switching contact with maximum voltage 12V Cable Two core cable with a cross section of 0 5 mm2 Maximum length 50 m CAUTION Not included with the product 2 1 3 Thermostatic valve TV1 1 TECHNICAL INFORMATION Thermostatic valve to regulate the water exchanger Suitable for all...

Page 10: ... the following Did you leave inside tools or objects that could damage the unit Is the supply of energy and heating water if applicable adequate Is the unit well closed Is the control module properly connected Does the unit have adequate protection according to the applicable standards CAUTION Interventions or changes to the internal connections are forbidden and shall result in the loss of warran...

Page 11: ...he control panel so up to 2 control panels may be connected to the MASTER regulator Options CP 1 control panel s address is 1 CP 2 control panel s address is 2 Electric connection Option 1 CP 1 CP 2 CAUTION Each panel must have its own address otherwise it may result in the malfunction of the regulator Terminals must be set if multiple panels are to be connected They are found in the main electron...

Page 12: ...round 10kW 60 Exchanger s return sensor malfunction 53 54 Unit out of order Temperature sensor malfunction on terminals 53 54 Check that the sensor is correctly connected to the electronics or test it measuring its resistance the resistance value at 20 C is around 10kW 61 Room temperature sensor malfunction 55 56 Unit out of order Temperature sensor malfunction on terminals 55 56 Check that the se...

Page 13: ...d in the list available at the supplier s Give the following information to the supplier or service type designation of the air curtain accessories in use place of installation serial number conditions of the installation incl electrical period of operation detailed description of the malfunction 7 2 DECOMMISSIONING THE PRODUCT LIQUIDATOIN Before scrapping the product make it unusable Old products...

Page 14: ... 24 IN 1 IN 2 L L H1 H2 ERR ALARM HEAT L L Fu 57 58 59 60 61 62 31 56 55 54 53 52 51 50 48 49 47 46 45 44 43 42 27 28 29 30 25 26 W PUMP I BUS OUTPUT JTAG JP4 JP3 JP2 JP1 CANL CANH GND 12V B A PWM NOT USED REF OUT NOT USED INLET AIR OUTLET AIR NOT USED RELAY RELAY zdroj 12V N L 1 2 3 Out AC3 v1 SSR 4 1 2 3 SSR 4 1 3 2 NTC 10K CANL CANH GND 12V B A SD SLOT 4 65 66 63 64 GND 12V B A 8 7 6 5 4 3 2 1 ...

Page 15: ...24 12V ALARM HEAT N ROOM OUT WATER HEAT H2 L H1 MODBUS RTU SLAVE UNIT INLET GND GND GND 4 5 6 7 8 9 10 11 12 13 14 15 B 2 3 1 A GND 12V SUPPLY CTRL THER DOOR MODBUS RTU USED MASTER UNIT OUTLET AIR POWER ROOM EXT NOT NTC 10K 2 MODRÁ BÍLÁ 1 6 7 8 2 3 4 5 1 RUDÁ 4 6 8 7 5 3 8 7 6 5 4 3 2 1 3 2 1 NTC 10K Název VCS R4 SU E SL AC Firma 2VV 1 2 3 4 5 6 7 8 9 33 35 37 34 36 38 10 11 39 40 41 42 19 14 13 2...

Page 16: ...XT RUN USED 0 10V ROOM RELAY RELAY GND 1 2 3 4 5 6 7 8 9 11 10 12 13 14 15 16 17 18 19 20 21 22 23 24 IN 1 IN 2 L L H1 H2 ERR ALARM HEAT L L Fu 57 58 59 60 61 62 31 56 55 54 53 52 51 50 48 49 47 46 45 44 43 42 27 28 29 30 25 26 W PUMP I BUS OUTPUT JTAG JP4 JP3 JP2 JP1 CANL CANH GND 12V B A PWM NOT USED REF OUT NOT USED INLET AIR OUTLET AIR NOT USED RELAY RELAY 1 2 3 Out AC3 v1 4 65 66 63 64 GND 12...

Page 17: ...9 30 ANALOG HEAT L 19 20 16 17 18 GND GND 25 26 27 28 B A GND 21 22 23 24 12V ALARM HEAT N ROOM OUT WATER HEAT H2 L H1 MODBUS RTU SLAVE UNIT INLET GND GND GND 4 5 6 7 8 9 10 11 12 13 14 15 B 2 3 1 A GND 12V SUPPLY CTRL THER DOOR MODBUS RTU USED MASTER UNIT OUTLET AIR POWER ROOM EXT NOT NTC 10K zdroj 12V N L 6 7 8 2 3 4 5 1 8 7 6 5 4 3 2 1 zdroj 24V N L 1 2 3 4 5 6 7 19 9 8 10 25 13 11 12 20 21 22 ...

Page 18: ...0V ROOM RELAY RELAY GND 1 2 3 4 5 6 7 8 9 11 10 12 13 14 15 16 17 18 19 20 21 22 23 24 IN 1 IN 2 L L H1 H2 ERR ALARM HEAT L L Fu 57 58 59 60 61 62 31 56 55 54 53 52 51 50 48 49 47 46 45 44 43 42 27 28 29 30 25 26 W PUMP I BUS OUTPUT JTAG JP4 JP3 JP2 JP1 CANL CANH GND 12V B A PWM NOT USED REF OUT NOT USED INLET AIR OUTLET AIR NOT USED RELAY RELAY 1 2 3 Out AC3 v1 4 65 66 63 64 GND 12V B A Název VCS...

Page 19: ...6 27 28 B A GND 21 22 23 24 12V ALARM HEAT N ROOM OUT WATER HEAT H2 L H1 MODBUS RTU SLAVE UNIT INLET GND GND GND 4 5 6 7 8 9 10 11 12 13 14 15 B 2 3 1 A GND 12V SUPPLY CTRL THER DOOR MODBUS RTU USED MASTER UNIT OUTLET AIR POWER ROOM EXT NOT NTC 10K NTC 10K zdroj 12V N L 6 7 8 2 3 4 5 1 2 3 1 Název VCS R4 SU S SL AC Firma 2VV 1 4 5 6 7 3 13 15 8 Kreslil Konvalina Datum 27 11 2019 Verze 1 Číslo 2 60...

Page 20: ...d your business since 1995 9 CONCLUSION 9 CONCLUSION In case of any doubt or query do not hesitate to contact our sales or technical support departments CONTACT Address 2VV s r o Fáblovka 568 533 52 Pardubice Česká republika Internet http www 2vv cz ...

Reviews: