14
TV1/1
6.2 CONNECT THE WATER INTAKE AND OUTLET HOSES
VCF-x-xxx-V(W)-...
•
A flexible hoses with a G3/4“ connection
•
Connection and pressure testing of the heater must be carried out by a person with professional
plumbing knowledge, who must observe current standards and regulations of the given country.
•
The maximum water temperature is +100° C. The maximum pressure is 1.6 MPa. We recommend
installing a stop valve on the intake and outlet of the heater to allow the water supply to be shut off .
6.2-1
Regulating the water coil with a thermostatic valve TV1/1
(Air curtains with water coil and BASIC control module: VCS-R2-BA-V-xx)
Thermostatic valve TV1/1 is an required accessorie for control module VCS-R2-BA-V-xx
Detailed description of water coil regulation by thermostatic valve (TV1/1), including it´s
connection, refer the instruction manual for thermostatic valve TV1/1.
3/4"
3/4"
VCF-x-xxx-V(W)-...
+
VCS-R2-BA-V-xx
6. INSTALLATION