6.1-3 Measure the installation site

• 

Only nonflammable materials (those that do not burn, smoulder or carbonise) or fire-resistant ma-

terials (those that do not burn, but mainly smoulder, e.g., plaster board) can be kept within 100 mm 

in any direction of the air curtain. However, these materials should not block the intake or outlet 

openings.

• 

For air curtains with an electric heater, safe distances from building structural surfaces and flammable 

objects are as follows:

• 

The safe distance for flammable materials in the direction of the main air flow (i.e., behind the outlet) 

is 500 mm,

• 

The safe distance for flammable materials above the air curtain is 500 mm,

• 

The safe distance for flammable materials in other directions is 100 mm.

Recommended size of ceiling aperture 

for inserting the curtain:

 

Type

A

[mm]

B

[mm]

VCFI4x-100-...EC 

1140

620

VCFI4x-150-...EC 

1640

620

VCFI4x-200-...EC 

2140

620

VCFI4x-250-...EC 

2520

620

• 

Air curtain is fixed to the ceiling by 4 threaded rods, which are not included delivery.

• 

It is necessary to ensure proper in the supply at the site according to the exact type of use of the air 

curtain and based on its electric parameters.

• 

When using water heated air curtain, please ensure connection of the flow and return pipes. 

• 

It is necessary to cut or otherwise make a hole according to the hereunder mentioned dimensions

• 

Drill four holes into the ceiling construction according to the dimensions scheme (see “Dimensions”) 

for hanging of the air curtain to 4 anchoring points.

• 

Screw the air curtain directly to the ceiling without any space between its casing and ceiling, or use 

four threaded bars to reach the required distance from the ceiling, according to the situation on the 

site (see “Conditions for safety and proper function of the air curtain”).

For wall installation use „Wall mounted bracket set“: VCS4-KONZ-STE. „Wall mounted bracket 

SET“ has to be ordered separately as an optional accessorie.   

 

 

 

6. INSTALLATION

A

B

OK

OK

3x 

9

10

150

220

280

114

57

470

40

38

L2

M8

M8

M8

M8

L1

Summary of Contents for FINESSE EC

Page 1: ...EN FINESSE EC INSTALLATION...

Page 2: ...ght to make changes including to technical documentation without prior notice Save this user manual for further use The instructions in this manual are a part of the product Statement of compliance Yo...

Page 3: ...ce If the complaint is not fi led in time your claim may not be valid later Checktoseeifitisthesameproductyouorde rot If there are any discrepancies do not un pack the curtain and immediately report t...

Page 4: ...Power supply cable plug Power supply connectors and fusse location Control modul socket Outlet grid 4 DIMENSIONS 594 6 299 3 304 1 25 596 5 638 5 250 A B C Type Spacing of installation holes A mm Len...

Page 5: ...50 60 33 VCFI4C150 S0EC 0 72 230 4 4 50 60 43 VCFI4C200 S0EC 0 90 230 5 3 50 60 58 VCFI4C250 S0EC 1 20 230 7 3 50 60 67 VCFI4C100 E1EC 9 96 400 17 50 60 36 VCFI4C150 E1EC 15 72 400 26 50 60 48 VCFI4C...

Page 6: ...over the door opening All separation distances for flammable materials and safe use of air curtain has to be kept The installed position of the air curtain can be chosen to accommodate the service ho...

Page 7: ...640 620 VCFI4x 200 EC 2140 620 VCFI4x 250 EC 2520 620 Air curtain is fixed to the ceiling by 4 threaded rods which are not included delivery It is necessary to ensure proper in the supply at the site...

Page 8: ...C 250 2085 VCFI4x 250 EC 250 2465 6 1 4 Suspend the air curtain on the threaded bars and ensure that the suspension will not come loose In consideration of the air curtain weight into account it is ne...

Page 9: ...ature is 100 C The maximum pressure is 1 6 MPa We recommend installing a stop valve on the intake and outlet of the heater to allow the water supply to be shut off 3 4 3 4 6 INSTALLATION 6 2 1 Regulat...

Page 10: ...e main electrical supply has been turned off If the product is connected to any control system other than the original one the regulation and me asurement components must be connected by the company t...

Page 11: ...electrical supply network disconnecting all poles of the network The electrical enclosure of the air curtain is IP 20 FINESSE air curtains are equipped with a fuse with T characteristic slow blow This...

Page 12: ...lutions for you and your business since 1995 ver 1 03 01 22 6 INSTALLATION Connection to the regulation control panel and accessories a b c d e Connect the remote control and accesso ries to the termi...

Page 13: ...M EC S0 VCST4 AGBA1 M EC V1 AirGENIO BASIC DOOR CONTACT M DOOR CONTACT ACTUATOR VALVE DOOR CONTACT N PE L CYKY 3Cx1 5 230V 50Hz N PE L FUSE 1 7 8 6 5 2 3 4 4 5 1 2 3 DK2 DK1 8 7 6 5 4 3 2 1 2 1 3 2 1...

Page 14: ...54 51 52 CONTACT INCENDIE CMSI 62 61 BOOST BOOST 57 58 boitier de commande J1 J2 5 26 27 28 29 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 31 33 35 36 37 38 39 40 41 42 43 9 44 45 46 47 48 4...

Page 15: ...4 63 62 61 60 59 58 57 56 55 54 53 52 51 31 33 35 36 37 38 39 40 41 42 43 9 44 45 46 47 48 49 50 30 32 34 72 71 70 69 O L LO N GND GND 0 10V SSR SSR GND 0 10V 30VAC AP EXT 230VAC W PUMP ALARM HEATER R...

Page 16: ...62 61 BOOST BOOST 57 58 boitier de commande J1 J2 GND GND 15 13 14 9 8 7 10 5 4 3 2 1 6 12 11 16 17 18 19 20 21 22 23 24 82 83 81 80 79 78 77 76 75 74 73 25 26 27 28 29 68 67 66 65 64 63 62 61 60 59...

Page 17: ...65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 31 33 35 36 37 38 39 40 41 42 43 9 44 45 46 47 48 49 50 30 32 34 72 71 70 69 O N ND GND 0 10V SSR SSR GND 0 10V 30VAC PUMP ALARM HEATER RUN OUTPUT COOL HEA...

Page 18: ...you and your business since 1995 ver 1 03 01 22 SLAVE SLAVE SLAVE SLAVE MASTER A A A A A B B B B B GND GND GND GND GND MASTER A A A A A B B B B B GND GND GND GND GND AirGENIO COMFORT AirGENIO SUPERIOR...

Page 19: ...solutions for you and your business since 1995 ver 1 03 01 22 6 INSTALLATION 6 6 EXIT SIGN Exit sign marking of emergency exit For all types of VCFx air curtains Not included in delivery 6 7 COVERING...

Page 20: ...e The power and heating water supply are well connected The unit is properly covered The control panel is properly connected Duringthecommissioning checktheproperfunctionoftheunit fans heating Checkth...

Page 21: ...21 2VV Creating innovative solutions for you and your business since 1995 ver 1 03 01 22 7 FILTER INSTALLATION 1 2 3...

Page 22: ...oduct reference number serial number running time used accessories installation location installation condition including electrical detailed description of the problem and the steps that you have tak...

Page 23: ...r you and your business since 1995 ver 1 03 01 22 10 ELECTRICAL SCHEMES 1 2 3 4 5 6 7 8 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 L1 N PE...

Page 24: ...ince 1995 ver 1 03 01 22 1 2 3 4 5 6 7 8 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 L1...

Page 25: ...2 3 4 5 6 7 8 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue...

Page 26: ...2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue Whi...

Page 27: ...ur business since 1995 ver 1 03 01 22 1 2 3 4 5 6 7 8 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 L1 N PE 3 15A FUSE WHITE NTC 10k 1 2 3 4 5...

Page 28: ...er 1 03 01 22 1 2 3 4 5 6 7 8 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 L1 N PE 4A FUS...

Page 29: ...8 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1...

Page 30: ...ow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black B...

Page 31: ...4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 1 2 3 4 5 6 7 8 R1 R1 2x 1580W 230V R73 R1 R1 2x 1580W 230V R74 R1 R1 2x 1580W 230V R75 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blu...

Page 32: ...0W 230V R76 R1 R1 2x 1250W 230V R77 R1 R1 2x 1250W 230V R78 R1 R1 2x 1250W 230V R79 R1 R1 2x 1250W 230V R80 R1 R1 2x 1250W 230V R81 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blu...

Page 33: ...230V R83 R1 R1 2x 1580W 230V R84 R1 R1 2x 1580W 230V R85 R1 R1 2x 1580W 230V R86 R1 R1 2x 1580W 230V R87 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2...

Page 34: ...R1 2x 1250W 230V R55 R1 R1 2x 1250W 230V R56 R1 R1 2x 1250W 230V R57 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow Blue White 1 M 1 2 3 4 5 6 Gr yel Black Blue Yellow B...

Page 35: ...ter installing the air curtain read carefully the Manualfortheappropriateregulator In case of any doubt or query do not hesitate to contact our sales or technical support departments CONTACT Address 2...

Reviews: