16
Configure Input 1 and Input 2 for Open & Close
Status.
1 2
2 INPUTS
Contacts Or Limit Switch
to determine gate open
or closed
Connect to Input 1 or Input 2.
Input 1 allows the status to be
queried. Input 2 will send a text
on every activation.
Main PCB
Input 1 is configured to work as follows.
Wiring a set of contacts as shown in the wiring diagram, into input 1 will
allow for the following text command to be sent to determine the gate or
door status.
Send this text.
Receive This TxT Response
Gate status Status open
or OR
Door status
Status Closed
Note 1
:
If contacts are not fitted to the gate or door and wired to the
input then this message will always return “Status Open”
Input 2 is configured to send an SMS text on all gate or door
openings and closings.
Wire a set of contacts or a limit switch, to Input 2 as shown on the wiring
diagram and mount on the gate or door so that they separate when it
opens