2.5 Overview of LED Indicators
The
status is signaled by LED indicators on the device front side. Refer
2N
LiftGate
®
to the table below for the statuses.
LED Indicators
DEVICE STATUS
Indicates the general
system status.
Blue – device status OK, device operational
Blue, slow flashing – device error that does not affect the full
functionality of the device
Red – temporary error (to be solved automatically, e.g. provider
service failure)
Red, slow flashing – permanent error (admin intervention is
required, e.g. via the device web interface)
Red, fast flashing – HW error, on-site service intervention is
required (e.g. DSL short-circuit, battery error/defect)
POWER
Indicates the general
power supply status.
Blue – external supply is progress, battery is kept charged
Blue, short flashing – external supply in progress, low battery life
Blue, slow flashing – external supply in progress, battery is being
charged (90–100 %)
Blue, fast flashing – external supply in progress, battery is being
charged (0–90 %)
Red – battery supply in progress, battery capacity over 50%