Flush Mounting – Thermally Insulated Wall
What You Need:
Longer screws (depending on the thermal insulation thickness)
Hole: (112 × 220 × 70) mm
Cut out the thermal insulation layer using the template (the same as for classic brick
wall).
Caution
The hole depth depends on the insulation layer thickness. If the
insulation layer is rather thick, you may need longer screws! If there are
hollow bricks under the insulation, make sure that your screws pass
through the whole dowel (50 mm) and fix the dowel reliably.
Make sure that the dowel holes have the required diameter. If the
diameter is too large, the dowels may get loose. Use some suitable
building adhesive to keep the dowels in place.
Make sure that the hole depth is sufficient too! The dowel length is 50
mm and the screw length is 90 mm.
Suppose that all the required cables have been carried into the drilled hole. Now
follow the instructions applicable for classic brick flush mounting. However, remember
that thermally insulated walls show less strength than classic brick walls.
Summary of Contents for Helios IP Force
Page 1: ...www 2n cz 2N Helios IP Force Security IP Intercom Installation Manual Version 2 7 ...
Page 42: ...2N TELEKOMUNIKACE a s www 2n cz 42 110 ...
Page 43: ...2N TELEKOMUNIKACE a s www 2n cz 43 110 ...
Page 53: ...2N TELEKOMUNIKACE a s www 2n cz 53 110 2N Helios IP Force Connectors PCB Version 555v3 ...
Page 63: ...2N TELEKOMUNIKACE a s www 2n cz 63 110 ...
Page 67: ...2N TELEKOMUNIKACE a s www 2n cz 67 110 ...
Page 72: ...2N TELEKOMUNIKACE a s www 2n cz 72 110 ...
Page 77: ...2N TELEKOMUNIKACE a s www 2n cz 77 110 ...
Page 83: ...2N TELEKOMUNIKACE a s www 2n cz 83 110 Connection ...