1.4
Action.SetOutput
The
SetOutput
block defines the action necessary for setting of the intercom output
to the required level.
Parameters
Event
Define the event that launches the action.
Condition
Define the condition to be met to execute the action. This parameter is optional.
Output
Define the output to be set.
Valid values:
relay1
– relay 1 on basic unit
relay2
– relay 2 on basic unit
output1
– output 1 on basic unit
output2
– output 2 on basic unit
cr_relay1
– relay 1 on card reader
cr_relay2
– relay 2 on card reader
cr_output
– output 1 on card reader
redled
- red LED indicator
led1
– LED 1 indicator
led2
– LED 2 indicator
led3
– LED 3 indicator
There may be different lists of valid values for different 2N
®
Helios IP models;
refer to the Available Digital Inputs and Outputs subsection.
Level
Define the required output level. This parameter is optional.
Valid values:
0
– output deactivation
1
– output activation (default value)
Example
Activate Output1 if the event defined on row 2 arises:
Action.SetOutput: Output=output1; Event=2