background image

  4

 

Overview of module’s features in various regimes of operation 

Function

 

Regime of operation 

autonomous offline  online 

Definition of access rights using programming cards 

9

 

9

 

9

 

Signalization of reading a card and releasing the door lock 

9

 

9

 

9

 

Acoustic signalization of alarm situations 

9

 

9

 

9

 

Changing the parameters of regimes of operation and alarms 

 

9

 

9

 

Definition of access rights from the PC 

 

9

 

9

 

Visualization of the regime of the reading module, recording 
events in an archive in the PC, viewing and working with events 

 

 

9

 

Controlling the output of the reading module directly from the PC 

 

 

9

 

 

Technical parameters 

Dimensions 

105 x 90 x 20 mm 

Power supply 

10 

÷

 15 VDC 

Max. power input 

150 mA 

ID technology 

EM Marin, 125kHz 

Max. number of access cards in the memory 

748 

inputs 

2x logical, non-potential 

Output for door lock 

1x relay switch contact 2 A / 24 V 

Alarm output 

Transistor output 5 V / 5 mA 

Protective contact (tamper) 

Opto-electrical 

Max. reading distance 

Normally 8 cm with ISO cards 

Communication channel 

RS485 galvanic non-separated 

Alternative data output 

WIEGAND (configurable) 

Signalization 

2x LED + piezzo-buzzer 

Working temperature 

-25 

÷

 +60°C 

Max. relative humidity 

95%, without condensation 

Supply cable length 

0,5 m 

 

Configurable operational parameters 

Parameter 

Possible values 

Default value 

Lock release duration 

÷

 255 s 

7 s 

Acoustic signalization of lock releasing 

Yes / no 

Yes 

Maximum duration of door opening 

÷

 255 s 

30 s 

Duration of acoustic signalization of violation 

÷

 255 s 

30 s 

Duration of acoustic signalization of door broken open 

÷

 255 s 

30 s 

Duration of acoustic signalization of door open too long 

÷

 255 s 

0 s 

Function of the 2

nd

 input 

Leaving button / 
contact handle 

Leaving button 

 

Summary of Contents for APS Mini

Page 1: ...2N APS MINI Standalone Reader Module Order No 9134162WE Reader Module with Attendance Keypad Order No 9134167WE User and Service manual Version 2 1 ...

Page 2: ...WE EntryCom set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Build in reader module for EntryCom 91341631E RS485 Ethernet converter 9134164E PC mini reader 9134165E Chip card 9134166E Chip key fob ...

Page 3: ...omously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of events from the connected reading modules The reading module integrating all circuits necessary for one reading place and one door is the basic hardware element of the APS mini access system Regimes of operation Autonomous programming...

Page 4: ... in the memory 748 inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electrical Max reading distance Normally 8 cm with ISO cards Communication channel RS485 galvanic non separated Alternative data output WIEGAND configurable Signalization 2x LED piezzo buzzer Working temperature 25 60 C Max ...

Page 5: ...rsion insert the enclosed square screw nut 2 and fasten the module on the wall It is recommended to place an installation box for connection of incoming cables on the other side of the wall or in highly secured area with in out readers Shut the cover and lock it using enclosed screw Removal of the module can be performed in reverse order ...

Page 6: ...to keep the distance of at least 50 cm This distance can be negatively influenced by various metallic constructions in case of doubts it is recommended to carry out practical test on the spot before the final installation Proper functioning and the reading distance can also be influenced by metal surfaces close to the antenna Such objects absorb electromagnetic field and may disturb the antenna of...

Page 7: ...the handle can be used with ball handle door configuration Connecting the mother board with data bus RS485 It is possible to connect the data line RS485 to the cables A B and 0V Up to 32 reading modules 2N APS mini can be connected to this data line which consists of three conductors Data bus must be connected with cables designed for data transfer shielded cables or cables with twisted pairs of c...

Page 8: ... 200 bps and 1 stop bit The main menu of the program includes the following commands Program Æ Setup displays the screen for setup of the PC communication port and the service card code Start Stop PC module communication control Write writes the configuration of the general properties in the reader module Program Æ End ends the program The program desktop is divided into 3 parts The area for the r...

Page 9: ... the program is carried out after communication was initiated and after the button Save was pressed Result of the action is shown by the progress indicator in the second part of the status bar Modules 2N APS mini in the online regime can be controlled via programs APS mini Administrator APS mini Events and APS mini ED These allow besides programming the parameters of the modules also setting acces...

Page 10: ...ast card the reader will go to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that are to be rid of the access rights in the entry place in question After c 15 s after the last card the reader will go to the normal operational regime by itself Erasing al...

Page 11: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1468 v 2 1 ...

Reviews: