4
Overview of module’s features in various regimes of operation
Function
Regime of operation
autonomous offline online
Definition of access rights using programming cards
9
9
9
Signalization of reading a card and releasing the door lock
9
9
9
Acoustic signalization of alarm situations
9
9
9
Changing the parameters of regimes of operation and alarms
9
9
Definition of access rights from the PC
9
9
Visualization of the regime of the reading module, recording
events in an archive in the PC, viewing and working with events
9
Controlling the output of the reading module directly from the PC
9
Technical parameters
Dimensions
105 x 90 x 20 mm
Power supply
10
÷
15 VDC
Max. power input
150 mA
ID technology
EM Marin, 125kHz
Max. number of access cards in the memory
748
inputs
2x logical, non-potential
Output for door lock
1x relay switch contact 2 A / 24 V
Alarm output
Transistor output 5 V / 5 mA
Protective contact (tamper)
Opto-electrical
Max. reading distance
Normally 8 cm with ISO cards
Communication channel
RS485 galvanic non-separated
Alternative data output
WIEGAND (configurable)
Signalization
2x LED + piezzo-buzzer
Working temperature
-25
÷
+60°C
Max. relative humidity
95%, without condensation
Supply cable length
0,5 m
Configurable operational parameters
Parameter
Possible values
Default value
Lock release duration
0
÷
255 s
7 s
Acoustic signalization of lock releasing
Yes / no
Yes
Maximum duration of door opening
0
÷
255 s
30 s
Duration of acoustic signalization of violation
0
÷
255 s
30 s
Duration of acoustic signalization of door broken open
0
÷
255 s
30 s
Duration of acoustic signalization of door open too long
0
÷
255 s
0 s
Function of the 2
nd
input
Leaving button /
contact handle
Leaving button